53
IM FG410-01EN
d) AC+DClimitation
The maximum value for [AC amplitude + DC offset] is limited to ±10 V/open.
For example, if the AC amplitude is 5 Vp-p/open, the DC offset range is limited to the range from
-
7.5 V/open to +7.5 V/open.
The maximum value varies according to the output voltage range setting and the external addition
input setting.
p.58
,
p.61
4.4 Setting Methods for Main Items