MODBUS Communication
6
TI 12A01F01-62EN
2. MODBUS map
Data type for FLXA402 MODBUS map
Data type Denition
oat oating point (4byte)
IEEE754
NaN: 0x7FFFFFFF
int16 16 bit signed integer
uint16 16 bit unsigned integer
uint32 32 bit unsigned integer
ASCII character set (using one byte per
character), multiple registration possible
bit elds data assigning information on bit
Access (load/import) to multiple registration such as oat, uint32, ASCII etc. must be
implemented at once.
Latest revision does not support script, or arithmetic by multiple sensors.
Access
Function Function
Code
(hex)
Data
Access
BIt
Read Coils 01
Write Single Coil 05
Write Multiple Coils 0F
16 bits
Read Input Register 04
Read Holding Registers 03
Write Single Register 06
Write Multiple Register 10
Diagnostics Read Device Identication 2B
Apr. 19, 2019-00