27-4
SM80B22M02E
4. Option flag-1 setting
Various setting is prepared for corresponding DNV’s rule.
This flag is composed of 8 bits and the setting is done by the hexadecimal number
The contents of each bit are as follows;
<Exp.>
Without Compass automatic change-over function
...0
Without “HEADING ERRONEOUS” alarm
...0
RS232C port setting (for Normal PC)
...0
Automatic compass change-over function is always available.
...0
Without “RUDDER ERRONEOUS” alarm
...0
The rudder maintain function by servo loop alarm is available in [FU] mode.
...0
Without Rudder stop control status
...
1
(for DNV’s feed-back failure scenario)
The rudder is maintained at appearing servo loop alarm
...0
Set [40] as this setting, since each falgs become [01000000].
Default : 00000000 = [00] (refer to mark
in above table.)
DNV class(Without TCS) : 01000000 = [40]
TCS (other class) : 11100000 = [E0]
DNV class(With TCS) : 11000000 = [C0]
DNV class NAUT-AW : 11011001 = [D9]
(1)Press the
ENTER
ENTERENTER
ENTER
key after displayed "
Flag-1(Hex)=
"on the data display.
Data display becomes current setting mode.
←Cursor position is inputting point
The part of a ## is displayed current setting condition.
(2) Press
△
△△
△
+
++
+
or
▽
▽▽
▽
-
--
-
key to set the cursor point. Then change the data by turning the Set
course dial. Turn to the clockwise direction, data is increased and turn to the counter clockwise
direction, data is decreased. (Data is 0 to F hexadecimal number)
Default : [00] (refer to mark
in above table.)
(3)After input the hexadecimal number , then press
ENTER
ENTERENTER
ENTER
key.
D7
=0:Without Compass automatic change-over function
=1:With Compass automatic change-over function
=0:Without “HEADING ERRONEOUS” alarm
=1:With “HEADING ERRONEOUS” alarm
=0:RS232C port setting (for Normal PC)
=1:RS232C port setting (for special purpose)
=0:Automatic compass change-over function is always available.
=1:Automatic compass change-over is prohibited by the status of Heading monitoring alarm.
=0:Without “RUDDER ERRONEOUS” alarm
=1:With “RUDDER ERRONEOUS” alarm
=0:
The rudder maintain function by servo loop alarm is available in [FU] mode.
=1:
The rudder maintain function by servo loop alarm is available in [AUTO] or [NAVI] mode.
=0:Without Rudder stop control status