27-5
SM80B22M02E
5. Derivative gain multiplier setting for Track Control
The multiplier of derivative gain for Track Control[=NAVI mode] can be set in this setting mode.
Actual Derivative gain = Original gain based on gain table. x Multiplier value
Setting range : 0.00 to 9.99
Initial value : 1.00
CautionThe [0.00] should not be set for this setting because the setting range is not checked.
Press the
ENTER
ENTERENTER
ENTER
key after displayed "
Track GainD=#.##
"on the data display.
Data display becomes current setting mode.
Cursor position is inputting point
Press
+
++
+
or
-
--
-
key to set the cursor point. Then change the data by turning the Set
course dial. Turn to the clockwise direction, data is increased and turn to the counter clockwise
direction, data is decreased. (Data is 0 to 9 numbers)
After input the multiplier, then press
ENTER
ENTERENTER
ENTER
key.
Special Data
Track GainD<#.##
Special Data
Track GainD<1.00