27-12
SM80B22M02E
=0:
OFF COURSE ALARM is output as individual
alarm for annunciator unit.
=1:
OFF HEADING ALARM is output as individual
alarm for annunciator unit.
=0: Rudder freeze status is Normaly open.
=1: Rudder freeze status is Normaly close.
=0: -----(spare)
=1: -----
For INS-1 setting
=0:
Heading data of HTD message is kept in last
received value when gyro failure alarm
occurred.
=1:
Heading data of HTD message is output as a
null field when gyro failure alarm
occurred.
=0:
Set & Drift calculation is invalid.(Both
of Set&Drift data are treated as 0.0.)
=1: Set & Drift calculation is valid.
=0:
COG data of VTG message is not used as
heading.
=1: COG data of VTG message is used as heading.
=0: -----(spare)
=1: -----
=0: -----(spare)
=1: -----
=0:
RS232C port is usable as the signal for
PILOT RECORDER.
=1:
RS232C port is usable for checking PID
rudder command.
=0: -----(spare)
=1: -----
=0: -----(spare)
=1: -----
=0: -----(spare)
=1: -----
=0: Without Digital Remote Controller
=1: With Digital Remote Controller
=0: -----(spare)
=1: -----
=0: -----(spare)
=1: -----
=0: -----(spare)
=1: -----
D11 D10 D9D15 D14 D13 D12 D0D7D8 D3 D2 D1D6 D5 D4