11-
5
SM80B22M02E
1.6
Input the Block coefficient (Cb)
Block coefficient means ship’s shape is whether slim or not.
For example
Ferry ,container ship
0.50
0.60
Bulk carrier, Tanker
0.65
0.75
VLCC, Large Bulk carrier
0.78
0.85
(1)
When you are displayed "
Cb= X.XXXX
" on the data display ,then press
ENTER
ENTERENTER
ENTER
key.
The data display become under setting mode.
Cursor position is inputting point
Press
+
++
+
or
-
--
-
key to set the cursor point. Then change the data by turning the Set
course dial. Turn to the clockwise direction , data is increased and turn to the counter
clockwise direction ,data is decreased. (Data is 0 to 9 Numerical value)
After input the Cb data , then press
ENTER
ENTERENTER
ENTER
key.
1.7
Input the Area pf rudder (Ar)
Unit of the area is
(1)
When you are displayed "
Rud-Area=XXX.XX
" on the data display ,then press
ENTER
ENTERENTER
ENTER
key.
The data display become under setting mode.
Cursor position is inputting point
Press
+
++
+
or
-
--
-
key to set the cursor point. Then change the data by turning the Set
course dial. Turn to the clockwise direction , data is increased and turn to the counter
clockwise direction ,data is decreased. (Data is 0 to 9 Numerical value)
After input the Ar data , then press
ENTER
ENTERENTER
ENTER
key.
SHIP PARA. CALC
Cb< #.####
SHIP
PARA. CALC
Cb< 0.5400
SHIP PARA. CALC
Rud-Area<###.##
SHIP PARA. CALC
Rud-Area<053.00