16-3
IM DL850E-01EN
Maximum Number of Waveform Acquisitions
(Maximum number of history waveforms that can be stored in the acquisition memory)
The number of history waveforms that can be stored varies depending on the selected record length and the
installed memory options as follows:
Record Length Number of Waveforms
No options
(250 Mpoint)
/M1 Option
(1 Gpoint)
/M2 Option
(2 Gpoint)
1 kpoint 5000 5000 5000
2.5 kpoint 5000 5000 5000
5 kpoint 2976 5000 5000
10 kpoint 1487 5000 5000
25 kpoint 593 2381 5000
50 kpoint 295 1189 2381
100 kpoint 144 583 1168
250 kpoint 57 236 474
500 kpoint 28 116 235
1 Mpoint 13 54 111
2.5 Mpoint 4 22 46
5 Mpoint 1 10 22
10 Mpoint 1 4 10
25 Mpoint 1
1
1 3
50 Mpoint 1
2
1 1
100 Mpoint 1
3
1
1
1
250 Mpoint 1
4
1
2
1
1
500 Mpoint 1
3
1
2
1 Gpoint 1
4
1
3
2 Gpoint 1
4
1 Only eight channels’ worth of history waveforms are acquired.
2 Only four channels’ worth of history waveforms are acquired.
3 Only two channels’ worth of history waveforms are acquired.
4 Only one channel’s worth of history waveforms are acquired.
This record length cannot be set.
Display Range (Start and End Record)
Using record numbers, set the range of history waveforms to display when the display mode is set to All or
Average.
Selectable range: 0 to −(the number of waveform acquisitions −1)
List of History Waveforms (List)
The history waveform record numbers and the timestamps when the waveforms were acquired are listed.