2.1 Information to be added (1)
This manual gives instructions on handling, wiring, installation, maintenance, and general
specications. To ensure correct use, please read this manual and following documents.
Document No. Explanation
IM 01C50B01-01E Hardware (This manual)
IM 01C50T01-01E For HART protocol type
IM 01C50T02-01E For FOUNDATION Fieldbus communication type
IM 01C50T03-01E For BRAIN communication type
GS 01C50B01-00EN YTA110 Temperature Transmitter
GS 01C50B02-00EN YTA310/YTA320 Temperature Transmitter
GS 01C50T01-00EN Model YTA Series HART Communication
GS 01C50T02-00EN Model YTA Series Fieldbus Communication
These documents can be downloaded from the website of Yokogawa.
Website address: http://www.yokogawa.com/d/
2.2 Information to be added (2)
■ForSafeUseofProduct
(e) Product Disposal
The instrument should be disposed of in accordance with local and national legislation/regulations.
(f) Authorized Representative in EEA
In relation to the CE Marking, The authorized representative for this product in the EEA (European
Economic Area) is:
Yokogawa Europe B.V.
Euroweg 2, 3825 HD Amersfoort,The Netherlands
2.3 Change applicable standards and Type of Protection and Marking Code
Before Change After Change
ATEX Intrinsically Safe “ia”
Applicable Standard:
EN 60079-0:2012, EN 60079-11:2012,
EN 60079-26:2007
ATEX Intrinsically Safe “ia”
Applicable Standard:
EN 60079-0:2012+A11:2013,
EN 60079-11:2012
ATEX Flameproof Type and Dust
Ignition Proof Type
Applicable Standard:
EN 60079-0:2012,
EN 60079-1:2007, EN 60079-31:2009
Type of Protection and Marking Code:
II 2 G Ex d IIC T6/T5 Gb,
II 2 D Ex tb IIIC T70°C, T9C Db
ATEX Flameproof Type and Dust Ignition
Proof Type
Applicable Standard:
EN 60079-0:2012+A11:2013,
EN 60079-1:2014, EN 60079-31:2014
Type of Protection and Marking Code:
II 2 G Ex db IIC T6/T5 Gb,
II 2 D Ex tb IIIC T70°C / T90°C Db
ATEX Intrinsically Safe “ic”
Applicable Standard:
EN 60079-0:2012, EN 60079-11:2012
ATEX Intrinsically Safe “ic”
Applicable Standard:
EN 60079-0:2012+A11:2013,
EN 60079-11:2012
IECEx Flameproof Type and Dust Ignition
Proof Type
Applicable Standard:
IEC 60079-0:2011,
IEC 60079-1:2007-04, IEC 60079-31:2008
Type of Protection and Marking Code:
Ex d IIC T6/T5 Gb,
Ex tb IIIC T70°C, T90°C Db
IECEx Flameproof Type and Dust Ignition
Proof Type
Applicable Standard:
IEC 60079-0:2011,
IEC 60079-1:2014-06, IEC 60079-31:2013
Type of Protection and Marking Code:
Ex db IIC T6/T5 Gb,
Ex tb IIIC T70°C / T9C Db
Manual Change No. 16-007-2