<7.GeneralSpecications>
7-13
IM 01C50G01-01EN
7.3 OptionalSpecications(YTA610andYTA710)
Item Description
Code
Lightning protector
*4
Allowable current: Max. 6000A (8×20μs), repeating 1000A (8×20μs), 100 times A
Painting
*1*6
Color and coating change
Amplier cover only
*3
Color: Munsell code N1.5 Black
Coating: High anti-corrosion coating
P1
Color: Munsell code 7.5BG4/1.5, Jade green
Coating: High anti-corrosion coating
P2
Color: Metallic silver
Coating: High anti-corrosion coating
P7
Color and coating change
Amplier and terminal covers
*3
Color: Munsell code 7.5 R4/14, Red
Coating: High anti-corrosion coating
PR
Coating change High anti-corrosion coating X2
Output signal Low-side
in Transmitter failure
*10
Output signal Low-side: –5%, 3.2 mA DC or less.
Sensor burnout is also set to ‘Low’: –2.5%, 3.6 mA DC.
C1
NAMUR NE43
Compliant
*10
Output signal limits:
3.8 mA to 20.5 mA
Failure alarm down-scale: output status at CPU failure
and hardware error is –5%, 3.2 mA or less.
Sensor burnout is also set to Low: –2.5%, 3.6 mA DC.
C2
Failure alarm up-scale: output status at CPU failure and
hardware error is 110%, 21.6 mA or more.
In this case Sensor burnout is High: 110%, 21.6 mA DC
C3
Data Conguration
*2
Description into “Descriptor” parameter of HART protocol (max. 16 characters) CA
Wired tag plate SUS316 stainless steel tag plate wired onto transmitter N4
Sensor matching RTD sensor matching function CM1
Attached ameproof
packing adapter
*5*7
Electrical connection G1/2 female
Applicable cable: O.D.8.0 to 12 mm
2pc. V52
EAC approval and
Russian pattern
approval marking
*9*11
EAC approval and Russian pattern approval marking
VR
EAC approval marking
without Russian pattern
approval marking
*9*11
EAC approval marking without Russian pattern approval marking
VE
High ambient-temp
characteristic type
*8*9
Refer to Table 7.5 Temperature coefcient
R1
Note: The indication of the nameplate shows an initial shipment state.
*1: Not applicable for Stainless housing.
*2: Applicable for only HART type.
*3: Except for Amplier and terminal cover, color and coating are general specication.
*4: Lightning protector (surge absorber) can be removed from, or added to the equipment.
*5: Combination with other Explosion protected other than TIIS ameproof is not possible.
*6: The combination of X2 and P is not possible.
*7: Applicable for Electrical Connection code 4. (The thread of connection between YTA and CABLE GLAND is M20, and the thread of
connection between CABLE GLAND and CABLE is G1/2.)
*8: Not applicable for YTA610.
*9: Not applicable for BRAIN type.
*10: Not applicable for Fieldbus type.
*11: Combination with other Explosion protected other than EAC Explosion-proof type is not applicable.