EasyManua.ls Logo

York International P3HMX20F12001 User Manual

York International P3HMX20F12001
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
OIL-FIRED WARM AIR
FURNACE
P2HMX12F08001 P3HMX14F10001
P3HMX20F12001
(Upflow or Horizontal Models)
P3LBX12F08001 P3LBX14F12001
(Lowboy Models)
INTRODUCTION...............................................................2
HEAT LOSS......................................................................2
LOCATION OF UNIT ........................................................2
AIR CONDITIONING.........................................................4
COMBUSTION AIR...........................................................4
CHIMNEY VENTING.........................................................4
OIL TANK..........................................................................6
PIPING INSTALLATION ...................................................6
ELECTRICAL CONNECTIONS ........................................6
CIRCULATING AIR BLOWER..........................................7
OIL BURNER ....................................................................8
FURNACE INSTALLATION SET-UP................................9
MAINTENANCE AND SERVICE.....................................10
OPERATING INSTRUCTIONS .......................................10
TABLE A-1: BECKETT OIL BURNER SET-UP .............11
TABLE A-2: DIRECT DRIVE BLOWER SET-UP ...........11
TABLE A-3: DIRECT DRIVE BLOWER
CHARACTERISTICS ......................................................12
GENERAL DIMENSIONS – P*HMX MODELS ...............14
GENERAL DIMENSIONS – P3LBX MODELS................15
APPENDIX B: WIRING DIAGRAM.................................16
WIRING NOTES..............................................................17
R7184 DETAILED SEQUENCE OF OPERATION..........18
TABLE C-1: ST9103 DETAILED SEQUENCE OF
OPERATION...................................................................20
TABLE C-2: CAD CELL RESISTANCE ........................21
TABLE C-3: R7184 TROUBLESHOOTING...................21
TABLE C-4: SYSTEM AND GENERAL
TROUBLESHOOTING....................................................24
AIR FILTER LOCATIONS...............................................27
REPAIR PART LIST – P3HMX14F10001 &
P3HMX20F12001............................................................28
REPAIR PART LIST – P3LBX12F08001A &
P3LBX14F12001A..........................................................29
REPAIR PART LIST – P2HMX12F08001.......................30
REPLACEMENT PART CONTACT INFORMATION......31
INSTALLATION
MANUAL
CONTENTS
Read this manual completely before beginning
installation.
Important: These instructions must be kept with
the furnace for future reference.

Other manuals for York International P3HMX20F12001

Questions and Answers:

York International P3HMX20F12001 Specifications

General IconGeneral
BrandYork International
ModelP3HMX20F12001
CategoryFurnace
LanguageEnglish

Summary

FURNACE INTRODUCTION AND OVERVIEW

HEAT LOSS CALCULATION FOR FURNACE SIZING

FURNACE LOCATION AND CLEARANCES

HORIZONTAL FURNACE INSTALLATION

NON-SUSPENDED INSTALLATION GUIDELINES

SUSPENDED FURNACE INSTALLATION

AIR CONDITIONING INTEGRATION WITH FURNACE

COMBUSTION AIR REQUIREMENTS

CHIMNEY VENTING AND DRAFT REQUIREMENTS

DRAFT REGULATOR CONTROL FUNCTION

OIL TANK INSTALLATION AND CODE COMPLIANCE

OIL PIPING INSTALLATION PROCEDURES

ELECTRICAL CONNECTIONS AND WIRING CODES

CIRCULATING AIR BLOWER OPERATION AND ADJUSTMENTS

THERMOSTAT WIRING AND SETTINGS

ACCESSORY POWER AND WIRING GUIDELINES

GENERAL SAFETY PRECAUTIONS AND WARNINGS

OIL BURNER COMPONENTS AND INITIAL SETUP

OIL BURNER NOZZLE SELECTION GUIDE

BURNER ELECTRODE POSITIONING AND ADJUSTMENT

OIL BURNER SET-UP AND TESTING PREPARATION

FINAL FURNACE INSTALLATION SET-UP

FURNACE MAINTENANCE AND SERVICE

ROUTINE HOMEOWNER MAINTENANCE TASKS

Outlines essential monthly maintenance tasks for homeowners, focusing on air filter care and general inspection.

ANNUAL CONTRACTOR SERVICING PROCEDURES

Describes annual servicing procedures for contractors, including cleaning, inspection, and safety control testing.

FURNACE OPERATING INSTRUCTIONS

GENERAL DIMENSIONS P*HMX MODELS

GENERAL DIMENSIONS P3LBX MODELS

WIRING DIAGRAM APPENDIX B

WIRING NOTES AND CONNECTION DETAILS

CONTINUOUS FAN OPERATION AND ACCESSORY WIRING

Details wiring for continuous fan operation and powering accessories like EACs and humidifiers.

THERMOSTAT AND CONTROL WIRING

Explains thermostat wiring connections to the furnace and control board, referencing ST9103 EFT and R7184.

ELECTRICAL SAFETY WARNINGS AND HAZARDS

R7184 DETAILED SEQUENCE OF OPERATION

R7184 LED DIAGNOSTIC LIGHT AND CAD CELL FUNCTION

R7184 LED DIAGNOSTIC LIGHT FUNCTIONS

Explains the meaning of R7184 LED diagnostic light patterns for normal operation, faults, and lockout states.

CAD CELL CONDITION AND TESTING PROCEDURES

Describes how to check the cad cell status via the LED light and its resistance readings.

TROUBLESHOOTING PRELIMINARY STEPS AND PRECAUTIONS

SYSTEM AND GENERAL TROUBLESHOOTING GUIDE

FURNACE WILL NOT START TROUBLESHOOTING

Addresses issues where the furnace fails to start, covering thermostat, power, and primary control faults.

FURNACE MANUAL RESET REQUIRED TROUBLESHOOTING

Troubleshoots scenarios where the furnace starts but shuts off, requiring manual reset of the oil protector.

OIL BURNER SPUTTERING TROUBLESHOOTING

Diagnoses issues with the oil burner sputtering at the nozzle, including fuel, filter, and electrode checks.

EXCESSIVE FUEL OIL CONSUMPTION ISSUES

Addresses causes of excessive fuel oil consumption, such as high temperature rise, fuel leaks, or improper settings.

TOO MUCH SMOKE AND SOOT ISSUES

Explains reasons for excessive smoke and soot buildup, including combustion air, alignment, and heat exchanger issues.

FURNACE HEATING PERFORMANCE PROBLEMS

Troubleshoots why the furnace fails to adequately heat the home, checking airflow, thermostat, and limit controls.

UNEVEN HOME HEATING TROUBLESHOOTING

Addresses uneven heating issues, likely related to duct system balance or airflow distribution.

SUPPLY AIR TEMPERATURE ISSUES DIAGNOSIS

Diagnoses problems with supply air temperature being too hot, too cool, or cool initially, checking filters and ductwork.

AIR FILTER LOCATIONS AND IMAGES

REPAIR PARTS LIST P3HMX14F10001 P3HMX20F12001

REPAIR PARTS LIST P3LBX12F08001A P3LBX14F12001A

REPAIR PARTS LIST P2HMX12F08001

REPLACEMENT PART CONTACT INFORMATION