036-21106-005 Rev. B (0505)
4 Unitary Products Group
FOOTNOTES:
1. These orifices are factory mounted in the flow control device of each indoor coil and must be removed for TXV installation.
2. A TXV kit must be used with these coils to obtain system performance. (701,702,703 indicates 1TV07 ...series).
3. Systems matched with furnaces or air handlers not equipped with blower-off delays, may require blower Time Delay Kit #6918A5011.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of
interconnecting line tubing.
2. Verify the orifice size and additional charge required for specific evaporator coil in the system using the above table.
3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaporator + adder for line set.
5. If the orifice in the evaporator was changed, verify the evaporator nameplate has been marked with the correct orifice size.
G1NA036S17L 63
63 + 15 73 + 12
701 + 15 702 + 12
G1NA048S21D 78
73 + 12 78 + 0 87 + 0
702 + 12 702 + 0 703 + 0
G1NA048S24P 63
73 + 13 78 + 2 87 + 1
702 + 13 702 + 2 703 + 1
G1NA060S24T 78
–––––––
––––––703 + 0
G1NF024SOF 63
–––––––
–––––––
G1NF036SOF 67
59 + 12 63 + 0 73 + 7
701 + 12 701 + 0 702 + 7
G1NF048SOF 78
78 + 21 87 + 6
702 + 21 703 + 6
G1NF060SOF 87
–––––87 + 18
703 + 18
F2RP024N06(T) 61
53 + 4 59 + 4
701 + 4 701 + 4
F2RP030N06(T) 65
59 + 6 63 + 4
701 + 6 701 + 4
F2RP036N06(T) 75
63 + 4 73 + 8
701 + 4 702 + 8
F2RP042N06(T) 78
73 + 13 78 + 0
702 + 13 702 + 0
F2FP048N06(T) 84
73 + 16 78 + 10 87 + 11
702 + 16 702 + 10 703 + 11
F2FP060N06(T) 90
–––––87 + 15
703 + 15
703
5
+ 5
F2FV060N06(T) 90
–––––87 + 15
703 + 15 703 + 5
Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)
Outdoor Unit AC018X1222 AC024X1222 AC030X1222 AC036X1222 AC042X1221 AC048X1222 AC060X1224
Unit Orifice (s)
1
53 59 63 73 78 87
Factory R-22 Charge, lbs-oz. 4 - 9 4 - 7 5 - 8 5 - 3 6 - 13 7 - 7 8 - 15
Indoor Coil
Coil Orifice
4
Orifice or TXV Kit
2
- Additional Charge, Oz.
3