5331838-YTG-A-0317
6 Johnson Controls Unitary Products
APPLICATION & ACCESSORIES
Refer to Price Manual for specific model numbers.
Support Feet S1-HPRKIT-**: Kit of 5 support feet to raise unit
above snow or landscaping. Available in heights of 3", 6" or 12".
Anchor Bracket Kit S1-1HK0401: Firmly anchors unit to pad
or support structure. When properly installed, approved for
ground-mounted or roof-mounted applications.
Wall Mount Kit (S1-ACB-**): Includes two brackets to allow
outdoor unit to be securely mounted to a vertical wall. Mounting
hardware is field sourced according to the specific application.
Winter Cover Kit S1-CCVRE***: Custom fit winter cover pro-
tects AC condensing unit from debris during the off-season.
Must be removed prior to unit operation. See Price Pages or
Source1 SmartSearch for the correct cover for each application
Touch-up Paint S1-5130153****: Color matched aerosol paint
for touching up unit chassis and panels. See Price Pages or
Source1 SmartSearch for the correct color for each application.
Thermostat: These advanced, communicating, variable capac-
ity designs require the York Hx™ Touchscreen Thermostat (S1-
THXU280) available through Source1. For more information,
see the thermostat section of the Product Equipment Catalog.
Rated in accordance with ARI Standard 270.
UNIT OPERATION
COOLING OPERATION
During cooling operation, the main outdoor control will receive a
communicated demand signal along with the current space
temperature and setpoint. The control algorithm will then utilize
these signals to communicate the proper compressor speed,
OD fan speed, and ID blower CFM to match system output for
the required space load.
EMERGENCY HEAT
Emergency Heating mode is defined as a compressor speed
reference of zero and the backup heat source energized. In
other words, a 'W' signal present without any 'Y' signals pres-
ent. The control energizes 'W1 OUT' immediately when an
emergency heat signal “W” is received. The control energizes
“W2 OUT” based upon the stage delay setting in the thermostat
(default 120 minutes) after the “W1 OUT” output is energized.
During emergency heating mode, the control returns to standby
mode. The control passes the “W1 OUT” back to the ID unit
automatically if no “Y” is present.
SOUND POWER RATINGS - COOLING
High Stage Cooling Octave Band Sound Power Level (db re. 1-pW)
Model Numbers 63 125 250 500 1000 2000 4000 8000 dBA SQI
YXV24B21S 67 69 65 68 63 59 57 53 69 19.1
YXV36B21S 71 75 69 71 69 65 59 53 73 19.1
YXV48B21S 72 73 71 71 69 64 59 54 73 19.2
YXV60B21S 75 76 73 72 70 65 61 55 74 19.0
Low Stage Cooling Octave Band Sound Power Level (db re. 1-pW)
Model Numbers 63 125 250 500 1000 2000 4000 8000 dBA SQI
YXV24B21S 63 64 52 49 46 42 33 36 53 19.0
YXV36B21S 63 64 55 59 55 50 42 37 60 19.1
YXV48B21S 64 64 72 53 50 42 36 35 64 19.1
YXV60B21S 64 65 59 56 54 49 42 38 59 19.1