246723-YTG-L-0807
Unitary Products Group 5
Go to www.ari.org/aridirectory for the latest additional matches.
1 PH 13 SEER AC WITH AV / SV / F*FV VARIABLE SPEED
CZB01811 AV24 17 600 18.0 12.1 14.00 11.50
CZB02411 AV24 17 800 23.0 16.7 14.00 11.50
CZB03011 AV36 17 1000 30.0 21.9 14.00 11.50
CZB03611 AV36 17 1200 36.0 26.5 14.00 11.50
CZB04211 AV/SV48 24 1400 41.5 30.5 14.00 11.50
CZB04811
AV/SV48 24 1600 48.0 35.8 14.00 11.50
AV/SV60 24 1600 48.0 35.8 14.00 11.50
F*FV060 24 1600 48.0 36.5 13.25 11.00
CZB06011
AV/SV60 24 1800 57.0 40.8 14.00 11.50
F*FV060 24 1780 55.5 40.8 13.25 11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1 MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT MODEL
FURNACE
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER
1,2
EER
TOTAL SENS.
CZB01811
450
750
14,17 FC/MC/PC/UC18 600 18.0 12.1 13.00 11.00
14,17 FC/MC/PC/UC24 600 18.0 12.1 13.00 11.00
14,17 FC/MC/PC/UC30 600 18.0 12.1 13.00 11.00
14 HC18 570 18.0 12.1 13.00 11.00
CZB02411
600
1000
14,17 FC/MC/PC/UC24 800 23.2 16.9 13.00 11.00
14,17 FC/MC/PC/UC30 800 23.2 16.9 13.00 11.00
14 HC30 760 22.6 16.5 13.00 11.00
HD24 800 22.6 16.5 13.00 11.00
CZB03011
800
1200
14,17 FC/MC/PC/UC30 1000 29.8 21.7 13.00 11.00
14,17,21 FC/MC/PC/UC36 1000 30.0 21.9 13.00 11.00
17 HC36 950 30.0 21.9 13.00 11.00
HD36 1000 30.0 21.9 13.00 11.00
CZB03611
1000
1400
17, 21 FC/MC/PC35 1200 36.0 26.5 13.00 11.00
14,17,21 FC/MC/PC/UC36 1200 35.6 26.3 13.00 11.00
17,21 FC/MC/PC/UC42 1200 36.0 26.5 13.00 11.00
17 HC36 1140 36.0 26.5 13.00 11.00
HD36 1200 35.8 26.4 13.00 11.00
CZB04211
1200
1600
21,24 FC/MC/PC/UC48 1400 41.0 30.2 13.00 11.00
24 HC60 1330 40.5 29.8 13.00 11.00
HD60 1400 40.0 29.4 13.00 11.00
CZB04811
1400
1800
21,24 FC/MC/PC/UC60 1600 48.0 35.8 13.00 11.00
24 HC60 1600 48.0 35.8 13.00 11.00
HD60 1600 48.0 35.8 13.00 11.00
CZB06011
1600
2000
21,24 FC/MC/PC/UC60 1800 55.5 39.7 13.00 11.00
24 HC60 1800 55.5 39.7 13.00 11.00
HD60 1800 55.5 39.7 13.00 11.00
24 MC61 1800 56.0 40.0 13.00 11.00
1 Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
2 TXV = Use 1TV900 series kit.