246723-YTG-L-0807
Unitary Products Group 5
Go to www.ari.org/aridirectory for the latest additional matches.
1 PH 13 SEER AC WITH AV / SV / F*FV VARIABLE SPEED
CZB01811 AV24 17 – 600 18.0 12.1 14.00 11.50
CZB02411 AV24 17 – 800 23.0 16.7 14.00 11.50
CZB03011 AV36 17 – 1000 30.0 21.9 14.00 11.50
CZB03611 AV36 17 – 1200 36.0 26.5 14.00 11.50
CZB04211 AV/SV48 24 – 1400 41.5 30.5 14.00 11.50
CZB04811
AV/SV48 24 – 1600 48.0 35.8 14.00 11.50
AV/SV60 24 – 1600 48.0 35.8 14.00 11.50
F*FV060 24 – 1600 48.0 36.5 13.25 11.00
CZB06011
AV/SV60 24 – 1800 57.0 40.8 14.00 11.50
F*FV060 24 – 1780 55.5 40.8 13.25 11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1 MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
UNIT MODEL
FURNACE
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER
1,2
EER
TOTAL SENS.
CZB01811
450
750
14,17 FC/MC/PC/UC18 600 18.0 12.1 13.00 11.00
14,17 FC/MC/PC/UC24 600 18.0 12.1 13.00 11.00
14,17 FC/MC/PC/UC30 600 18.0 12.1 13.00 11.00
14 HC18 570 18.0 12.1 13.00 11.00
CZB02411
600
1000
14,17 FC/MC/PC/UC24 800 23.2 16.9 13.00 11.00
14,17 FC/MC/PC/UC30 800 23.2 16.9 13.00 11.00
14 HC30 760 22.6 16.5 13.00 11.00
– HD24 800 22.6 16.5 13.00 11.00
CZB03011
800
1200
14,17 FC/MC/PC/UC30 1000 29.8 21.7 13.00 11.00
14,17,21 FC/MC/PC/UC36 1000 30.0 21.9 13.00 11.00
17 HC36 950 30.0 21.9 13.00 11.00
– HD36 1000 30.0 21.9 13.00 11.00
CZB03611
1000
1400
17, 21 FC/MC/PC35 1200 36.0 26.5 13.00 11.00
14,17,21 FC/MC/PC/UC36 1200 35.6 26.3 13.00 11.00
17,21 FC/MC/PC/UC42 1200 36.0 26.5 13.00 11.00
17 HC36 1140 36.0 26.5 13.00 11.00
– HD36 1200 35.8 26.4 13.00 11.00
CZB04211
1200
1600
21,24 FC/MC/PC/UC48 1400 41.0 30.2 13.00 11.00
24 HC60 1330 40.5 29.8 13.00 11.00
– HD60 1400 40.0 29.4 13.00 11.00
CZB04811
1400
1800
21,24 FC/MC/PC/UC60 1600 48.0 35.8 13.00 11.00
24 HC60 1600 48.0 35.8 13.00 11.00
– HD60 1600 48.0 35.8 13.00 11.00
CZB06011
1600
2000
21,24 FC/MC/PC/UC60 1800 55.5 39.7 13.00 11.00
24 HC60 1800 55.5 39.7 13.00 11.00
– HD60 1800 55.5 39.7 13.00 11.00
24 MC61 1800 56.0 40.0 13.00 11.00
1 Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
2 TXV = Use 1TV900 series kit.