York CZF024 THRU 060 - Cooling Capacity - With Air Handler Coils (Continued)

York CZF024 THRU 060
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
567175-YTG-E-0512
6 Johnson Controls Unitary Products
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
CZF04813(C)
AHE48D 24 1600 45.0 33.2 15.00 12.50
AHE60D 24 1565 45.5 33.8 15.50 13.00
AHP48 24 1600 45.0 32.2 13.75 12.00
AHP60 24 1600 46.0 32.8 14.50 12.50
AHR48D 24 1610 45.5 32.6 13.75 12.00
AHR60D 24 1620 45.5 32.8 14.00 12.25
AHX48 24 1660 46.0 34.4 15.25 12.75
AHX60 24 1570 46.0 33.8 15.50 13.00
AV*48 24 1625 45.5 33.6 15.25 12.50
AV*60 24 1560 45.5 33.8 15.50 12.75
F6FP048 24 1625 45.5 33.6 15.00 12.50
F6FP060 24 1570 46.0 33.8 15.50 13.00
F4FV060 24 1600 45.0 33.6 15.00 12.50
MV16C 21 FC/MC48C 1625 45.0 33.0 14.50 12.50
MV20D 24 FC/MC48D 1620 45.0 33.2 14.75 12.75
MV16C 21 FC/PC60C 1600 44.5 32.8 14.00 11.75
MV20D 24 FC/MC60D 1600 45.0 33.2 15.00 12.50
MV20D 24 FC/MC62D 1630 45.5 33.8 15.50 12.75
MV20D 24 FC64D 1630 47.0 35.8 16.00 13.25
MX16C 21 FC/MC48C 1685 45.0 34.0 14.50 12.50
MX20D 24 FC/MC48D 1525 45.0 33.2 14.75 13.00
MX16C 21 FC/PC60C 1630 45.0 33.0 14.50 13.00
MX20D 24 FC/MC62D 1605 46.0 34.0 15.75 13.25
MX20D 24 FC64D 1605 47.0 36.0 16.50 13.50
CZF06013(C)
AHE60D 24 1835 53.5 38.0 15.25 13.00
AHR60D 24 1870 52.0 36.2 13.75 12.00
AHX60 24 1865 53.5 38.5 15.40 13.00
AV*60 24 1730 52.5 36.4 15.25 12.75
F6FP060 24 1865 53.5 38.5 15.40 13.00
MV20D 24 FC/MC60D 1845 53.0 37.3 15.00 12.75
MV20D 24 FC/MC62D 1855 53.5 38.0 15.00 12.75
MV20D 24 FC64D 1705 54.5 39.0 16.00 13.50
MX20D 24 FC/MC60D 1780 53.0 37.5 15.50 13.00
MX20D 24 FC/MC62D 1795 54.0 38.5 15.75 13.25
MX20D 24 FC64D 1795 55.0 40.0 16.25 13.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and AHRI Standard 210/240.
Cooling MBH based on 8°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
16 SEER AC WITH AIR HANDLERS