036-21320-002 Rev. A (1103)
Unitary Products Group 31
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO EABC-(T,W)060S
EVAPORATOR COIL MODEL NO G1FA060S21
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1500 1700 1900
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 71.6 5.22 4.02 72.4 5.14 4.14 73.2 5.05 4.25
70 70.5 5.66 3.68 70.8 5.56 3.77 71.2 5.45 3.86
80 69.3 6.10 3.33 69.3 5.98 3.40 69.2 5.85 3.47
47
60 60.0 4.65 3.78 60.4 4.62 3.84 60.7 4.58 3.89
70 58.8 5.08 3.43 59.0 4.97 3.48 60.0 4.99 3.56
80 57.6 5.50 3.07 58.5 5.45 3.15 59.3 5.40 3.22
40
60 53.5 4.42 3.55 54.2 4.41 3.61 54.9 4.40 3.66
70 52.1 4.81 3.20 52.7 4.78 3.26 53.4 4.75 3.32
80 50.6 5.21 2.85 51.3 5.16 2.92 51.9 5.11 2.98
30
60 46.0 4.19 3.22 46.6 4.18 3.27 47.2 4.17 3.32
70 44.8 4.58 2.90 45.7 4.56 2.96 46.6 4.55 3.03
80 43.5 4.96 2.57 44.7 4.95 2.65 46.0 4.94 2.73
17
60 38.0 3.99 2.79 38.4 3.99 2.82 38.8 3.99 2.85
70 37.0 4.35 2.52 37.0 3.72 2.92 37.9 3.79 2.93
80 36.0 4.71 2.24 36.5 4.69 2.28 37.0 4.68 2.32
10
60 33.7 3.89 2.56 34.0 3.89 2.58 34.3 3.90 2.60
70 32.8 4.23 2.31 33.0 4.23 2.33 33.2 4.22 2.35
80 32.0 4.58 2.06 32.1 4.56 2.08 32.2 4.54 2.10
Coil
MBH KW COP
G1UA060(S,H)21,24 1.00 1.00 1.00
G1HA060H24 0.99 1.00 0.99
G2FD060(S,H)24 1.00 1.00 1.00