EasyManua.ls Logo

York TIWM006B22S - Mounting Indoor Unit Onto a Poured Concrete Wall or Concrete Block Wall; Mounting Indoor Units

York TIWM006B22S
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
P5417090
When removing or replacing the unit, push
upward the "PUSH" part on the bottom to release
the bottom part of unit from the catches in the
mounting plate.
5.2.3 Mounting Indoor Unit onto a Poured Concrete Wall or Concrete Block Wall
Attach the mounting plate to a concrete wall or a concrete block wall with screws and plugs (anchors).
Install the mounting plate directly to the wall by the eld-supplied plug as shown in the gure below. Mount
the unit according to the plug depth specied by the manufacturer. Select the plug size from the table
below.
Plug (Anchor)
Size
Qty.
006 to 012 Type 015 to 030 Type
M4 - M5 4 5
5.2.4 Mounting Indoor Units
(1) Hook the upper part of the indoor unit to the mounting plate.
NOTE:
Avoid contact with refrigerant or refrigerant oil to the upper part of indoor unit.
If the unit cover plate comes into contact with these substances, wipe them off immediately and
completely.
(2) Insert the catches along the bottom of the indoor unit into corresponding locations on the mounting
plate.
Mounting this unit is a two-person job. The unit is too much to handle for one person and the risk
of injury exists.
Check to ensure that the unit is securely
hooked onto the mounting plate.
Aninsecurettingwillresultinunwanted
vibration when the unit is running.
A poorly mounted unit can separate from its
mountingplateandfalltotheoorwithserious
injuries.
Slowly hold up and
press the unit downward
to mounting plate.
Catch
Mounting
Plate
Cutout
Catch

Related product manuals