EasyManuals Logo

York Y9USC-09 B5R User Manual

York Y9USC-09 B5R
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
Service manual
9
a.Number of rows
2
3
b.Tube pitch(a)x row pitch(b)
mm
25.4x22
25.4x22
c.Fin spacing
mm
1.4
1.7
d.Fin type (code)
Hydrophilic aluminium
Hydrophilic aluminium
e.Tube outside dia.and type
mm
Ф9.53x0.27, innergroove tube
Ф9.53x0.27, innergroove tube
f.Coil length x height x width
mm
560x406x44
560x406x66
Condenser
g.Number of circuits
2
2
Outdoor air flow (Hi/Mi/Lo) m3/h
m3/h
1200/1100/1000
1200/1100/1000
Outdoor noise level (Hi/Mi/Lo) dB(A)
dB(A)
60/57/54
60/57/54
Dimension (W*H*D)
mm
660×435×640
660×435×640
Packing (W*H*D)
mm
750×520×740
750×520×740
Net/Gross weight
Kg
55/60
59/64
Operation temp
16 31
16 31
Ambient temp
17 ~ 43
-10 ~ 45
Application area
m2
30-40
30-40
Qty’per 20’& 40’HQ Fcl
Pieces
94/240
94/240
Note:
The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different as a result of
ambient condition.
The above design and specifications are subject to change without prior notice for product improvement.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York Y9USC-09 B5R and is the answer not in the manual?

York Y9USC-09 B5R Specifications

General IconGeneral
BrandYork
ModelY9USC-09 B5R
CategoryAir Conditioner
LanguageEnglish

Related product manuals