The compressor not to
stop even the room
temp. has got to the
setting temperature.
Check and replace if the thermostat is damaged.
Clean or replace if restricted.
Determine if the unit is properly sized for the area to be cooled or heated.
Clean or replace if restricted.
Check the fan capacitor and replace if not within +/-10% of manufactures rating.
Take proper measures to make the door and windows sealed well if gap is found.
Clean or remove if any barrier is found to block the inlet/outlet wind flow of the unit.
Add a awning if the condenser is exposed to the sunlight.
Check the tubes for reasons of leakage. Recycle the refrigerant, correct the leakage
points and recharge.
Regulate the flow if capillary tube and make the evaporating temperature
appropriate if the evaporator is frosted. Replace if blocked. Repair joint if leaking.
The inlet and outlet valve of the compressor is damaged, making the low pressure
connected with the high pressure. The refrigerating system can not produce high
pressure and low pressure. Replace the compressor after checking for the reason.
The seal in valve is damaged, making the low pressure connected with the high
pressure. The refrigerating system can not produce high pressure and low pressure.
Replace the reverse valve after checking for the reason.
Insufficient cooling or
heating.
The drainage is blocked. It will increase the efficiency in cooling mode, but will cause
the condenser to frost in heating mode.
The amount of the refrigerant is too much, making the compressor load too big.
Recycle and recharge the refrigerant after checking for the reason.
Stop instantly after
startup.
The compressor is seized. Replace after checking for the reason.
Check the voltage. Call an electrician if no within the limit.
Check the terminals. Repair and correct if loose.
Check and adjust the thermostat.
Check and adjust the main switch setting.
Check the resistance of reverse valve wire. Replace the wire if short, open or
damaged.
If the reverse valve is blocked, the heating mode will not perform. Replace the
reverse valve after checking the reason.