YORK INTERNATIONAL
7
FORM 201.19-W3 (1104)
ELECTRICAL DATA
SYSTEM #2 FIELD-SUPPLIED WIRING
Over-current
Model
Volts MRA
1
Min. NF
Protection
13
Factory Provided (Lugs) Wire Range
7
Compressor Fans
11, 12
YCAS
(MCA)
Disc. Sw.
2,9
Min.
3, 5
Max.
4, 6
Std. Terminal Optional NF. Optional
RLA Y-LRA X-LRA Qty.
FLA LRA
Block Disc. Sw. Circuit Breaker
(Ea.) (Ea.)
0373 380 148 150 200 250 # 2 - 4/0 # 4 - 300 # 6 - 350 108 241 761 3 4.4 17.1
0403 380 160 200 200 250 # 2 - 4/0 # 4 - 300 # 6 - 350 118 241 761 3 4.4 17.1
0453 380 188 200 225 300 1/0 - 300 # 6 - 350 # 6 - 350 140 309 979 3 4.4 17.1
0503 380 215 250 300 350 1/0 - 500 # 6 - 350 (2) 3/0-250 161 309 979 3 4.4 17.1
0543 380 193 200 250 300 1/0 - 300 # 6 - 350 # 6 - 350 141 309 979 4 4.4 17.1
0573 380 227 250 300 350 2/0 - 500 # 6 - 350 (2) 3/0-250 168 309 979 4 4.4 17.1
0623 380 247 250 300 400 2/0 - 500 # 6 - 350 (2) 3/0-250 183 309 979 4 4.4 17.1
0653 380 232 250 300 350 2/0 - 500 # 6 - 350 (2) 3/0-250 168 309 979 5 4.4 17.1