5855836-YTG-B-1121
44 Johnson Controls Ducted Systems
Multipliers for determining the performance with other indoor sections.
TPLC060A12MP13C XAHB24B 1.05 1.08 0.92
TPLC080B12MP13C CF/CM/CU18B 1.01 1.00 0.92
TPLC080B12MP13C XAFB24B 1.05 1.07 0.93
YP9C060B12MP13C CF/CM/CU18B 1.01 1.00 0.92
YP9C060B12MP13C XAFB24B 1.05 1.06 0.93
YP9C080B12MP13C CF/CM/CU18B 1.01 1.00 0.92
YP9C080B12MP13C XAFB24B 1.05 1.07 0.92
YP9C080B12MP13C XAHB24B 1.05 1.08 0.92
YPLC060A12MP13C CF/CM/CU18B 1.01 1.01 0.92
FURNACE MULTIPLIERS - 1.5 TON (Continued)
Furnaces Coil T.C. S.C. KW
YPLC060A12MP13C CF/CM18A 1.01 1.00 0.92
YPLC060A12MP13C XAF/XAUA24B 1.05 1.07 0.92
YPLC060A12MP13C XAFB24B 1.05 1.06 0.91
YPLC060A12MP13C XAHA24B 1.05 1.08 0.92
YPLC060A12MP13C XAHB24B 1.05 1.08 0.92
YPLC080B12MP13C CF/CM/CU18B 1.01 1.00 0.92
YPLC080B12MP13C XAFB24B 1.05 1.07 0.93
FURNACE MULTIPLIERS - 1.5 TON (Continued)
Furnaces Coil T.C. S.C. KW
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YEE18B21S
AIR TEMPERATURE
ENTERING
OUTDOOR UNIT (°F)
AIR TEMPERATURE
ENTERING
INDOOR COIL (°F)
ID CFM
450 600 750
MBH COP KW MBH COP KW MBH COP KW
60
60 19.4 3.85 1.47 20.2 4.12 1.43 21.0 4.41 1.39
70 18.9 3.44 1.61 19.6 3.66 1.57 20.3 3.90 1.52
80 18.4 3.09 1.75 19.0 3.28 1.70 19.6 3.48 1.65
47
60 16.7 3.46 1.41 17.3 3.65 1.39 18.0 3.86 1.37
70 16.3 3.08 1.55
16.8 3.24 1.52 17.4 3.42 1.49
80 15.8 2.76 1.68 16.3 2.90 1.65 16.8 3.04 1.62
40
60 15.2 3.23 1.38 15.8 3.39 1.37 16.4 3.55 1.35
70 14.8 2.87 1.52 15.4 3.01 1.50 15.9 3.15 1.48
80 14.5 2.57 1.65 14.9 2.68 1.63 15.3 2.80 1.60
30
60 13.2 2.89 1.33 13.7 3.00 1.33 14.2 3.11 1.33
70 12.8 2.56 1.47 13.2 2.65 1.46 13.7 2.75 1.46
80 12.5 2.29 1.60 12.8 2.37 1.59 13.2 2.45 1.58
17
60 10.5 2.41 1.27 10.8 2.46 1.29 11.2 2.51 1.31
70 10.2 2.13 1.41 10.5 2.17 1.42 10.8 2.22 1.43
80 9.9 1.89 1.54 10.2 1.93 1.55 10.4 1.97 1.55
10
60 9.0 2.13 1.24 9.3 2.15 1.27 9.6 2.18 1.30
70 8.8 1.88 1.37 9.0 1.90 1.39 9.3 1.92 1.42
80 8.6 1.67 1.51 8.8 1.69 1.52 8.9 1.70 1.53
0
60 6.9 1.70 1.19 7.2 1.70 1.24 7.4 1.69 1.28
70 6.8 1.50 1.33 6.9 1.49 1.36 7.1 1.49 1.39
80 6.6 1.33 1.46 6.7 1.32 1.49 6.8 1.32 1.51
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR AND INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
COIL MULTIPLIERS - 1.5 TON
Air Handler Coil MBH COP KW
AE18BX21 0.95 1.05 0.90
AVC18BX21 0.93 1.07 0.87
ME08BN21 XAFB24B 0.99 1.07 0.92
ME08BN21 XAHB24B 1.00 1.10 0.91
ME12BN21 CF/CM18B 0.93 1.07 0.86
ME12BN21 XAFB24B 0.98 1.08 0.91
ME12BN21 XAHB24B 0.99 1.10 0.90
FURNACE MULTIPLIERS - 1.5 TON
Furnaces Coil MBH COP KW
TL8E060A12UH11 CF/CM/CU18B 0.94 1.06 0.88
TL8E060A12UH11 XAF/XAUA24B 0.99 1.06 0.93
TL8E060A12UH11 XAFB24B 0.98 1.06 0.92
TL8E060A12UH11 XAHA24B 1.00 1.08 0.92
TL8E060A12UH11 XAHB24B 1.00 1.09 0.91
TL9E060B12UH11 CF/CM/CU18B 0.93 1.05 0.89
TL9E060B12UH11 XAFB24B 0.99 1.06 0.93
TL9E060B12UH11 XAHB24B 1.00 1.09 0.92
TM8E040A12MP11 CF/CM/CU18B 0.93 1.06 0.88
TM8E040A12MP11 CF/CM18A 0.94 1.06 0.89
TM8E040A12MP11 XAF/XAUA24B 0.98 1.06 0.92
TM8E040A12MP11 XAFB24B 0.98 1.06 0.92
TM8E040A12MP11 XAHA24B 1.00 1.09 0.92