Loading...
5855836-YTG-B-1121
Johnson Controls Ducted Systems 77
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Multipliers for determining the performance with other indoor sections.
COIL MULTIPLIERS - 5 TON
Air Handler Coil T.C. S.C. KW
AE60DX21 1.02 1.04 0.94
AVC60DX21 1.02 1.02 0.92
ME20DN21 CF/CM64DXA1 1.02 1.03 0.91
ME20DN21 XAHD60J 1.05 1.08 0.97
MVC20DN21 CF/CM64DXA1 1.02 1.03 0.91
MVC20DN21 XAHD60J 1.04 1.08 0.97
FURNACE MULTIPLIERS - 5 TON
Furnaces Coil T.C. S.C. KW
TM8E080C20MP11 CF/CM64DXA1 1.02 1.03 0.93
TM8E100C20MP11 CF/CM64DXA1 1.02 1.03 0.94
TM8E120C20MP11 CF/CM64DXA1 1.02 1.03 0.93
TM9E080C20MP12 CF/CM64DXA1 1.02 1.02 0.93
TM9E100C20MP12 CF/CM64DXA1 1.02 1.03 0.93
TMLE080C20MP11 CF/CM64DXA1 1.02 1.03 0.93
TMLE100C20MP11 CF/CM64DXA1 1.02 1.03 0.94
TMLE120C20MP11 CF/CM64DXA1 1.02 1.03 0.93
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YEE60B21S
AIR TEMPERATURE
ENTERING
OUTDOOR UNIT (°F)
AIR TEMPERATURE
ENTERING
INDOOR COIL (°F)
ID CFM
1500 1750 2000
MBH COP KW MBH COP KW MBH COP KW
60
60 69.2 4.56 4.45 70.3 4.76 4.33 71.3 4.97 4.21
70 67.4 4.05 4.88 68.5 4.23 4.75 69.5 4.41 4.62
80 65.6 3.62 5.31 66.7 3.78 5.17 67.7 3.94 5.03
47
60 58.9 4.09 4.22 59.9 4.24 4.14 60.9 4.39 4.06
70 57.1 3.61 4.63 58.1 3.75 4.54 59.1 3.89 4.46
80 55.3 3.21 5.04 56.4 3.34 4.95 57.4 3.46 4.86
40
60 52.9 3.79 4.09 53.4 3.87 4.04 53.9 3.95 4.00
70 50.6 3.30 4.49 51.3 3.39 4.44 52.1 3.47 4.39
80 48.4 2.89 4.90 49.3 2.98 4.84 50.2 3.07 4.79
30
60 45.0 3.35 3.94 45.9 3.44 3.91 46.9 3.53 3.89
70 44.4 3.01 4.31 45.2 3.09 4.28 46.1 3.17 4.25
80 43.8 2.74 4.69 44.5 2.80 4.66 45.3 2.87 4.62
17
60 37.6 2.94 3.75 37.4 2.96 3.70 37.1 2.98 3.65
70 36.0 2.59 4.08 36.6 2.64 4.06 37.2 2.70 4.03
80 34.5 2.29 4.42 35.9 2.38 4.41 37.2 2.47 4.41
10
60 32.5 2.64 3.61 33.4 2.70 3.63 34.3 2.75 3.66
70 31.7 2.35 3.95 32.3 2.39 3.96 32.9 2.43 3.97
80 30.9 2.11 4.29 31.2 2.13 4.29 31.5 2.16 4.29
0
60 25.6 2.29 3.27 28.2 2.40 3.44 30.8 2.52 3.58
70 25.9 2.09 3.62 26.6 2.11 3.70 27.3 2.12 3.76
80 26.1 1.93 3.97 24.9 1.85 3.96 23.7 1.76 3.94
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR AND INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
COIL MULTIPLIERS - 5 TON
Air Handler Coil T.C. S.C. KW
AE60DX21 0.97 1.00 0.97
AVC60DX21 0.98 1.03 0.95
ME20DN21 CF/CM64DXA1 0.97 1.02 0.95
ME20DN21 XAHD60J 1.00 1.01 0.99
MVC20DN21 CF/CM64DXA1 0.97 1.02 0.95
MVC20DN21 XAHD60J 0.99 1.00 0.99
FURNACE MULTIPLIERS - 5 TON
Furnaces Coil T.C. S.C. KW
TM8E080C20MP11 CF/CM64DXA1 0.97 1.02 0.95
TM8E100C20MP11 CF/CM64DXA1 0.97 1.02 0.95
TM8E120C20MP11 CF/CM64DXA1 0.97 1.03 0.95
TM9E080C20MP12 CF/CM64DXA1 0.97 1.02 0.95
TM9E100C20MP12 CF/CM64DXA1 0.97 1.03 0.95
TMLE080C20MP11 CF/CM64DXA1 0.97 1.02 0.95
TMLE100C20MP11 CF/CM64DXA1 0.97 1.02 0.95
TMLE120C20MP11 CF/CM64DXA1 0.97 1.03 0.95