48 Johnson Controls Unitary Products
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings) - CANADA
ONLY
UNIT MODEL
COIL
CFM RANGE
(MIN.-MAX.)
STAGE
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.
14 SEER HP COIL ONLY RATINGS
YHJD18S41S7 FC/MC/PC24
14.5, 17.5
450 - 750
600 18.0 13.3 13.00 11.00
YHJD18S41S7 FC/MC/PC30
14.5, 17.5
450 - 750
600 18.0 13.3 13.00 11.00
YHJD18S41S7 FC/MC/PC32 14.5 450 - 750
600 18.0 13.4 13.00 11.00
YHJD18S41S7 FC/MC/PC35
17.5, 21.0
450 - 750
600 18.0 13.4 13.00 11.00
YHJD24S41S7 FC/MC/PC32 14.5 600 - 1000
800 22.6 17.7 13.00 11.00
YHJD24S41S7 FC/MC/PC35
17.5, 21.0
600 - 1000
800 22.6 17.7 13.00 11.00
YHJD24S41S7 FC/MC/PC37 14.5 600 - 1000
800 22.6 17.9 13.00 11.00
YHJD24S41S7 FC/MC/PC43
17.5, 21.0
600 - 1000
800 22.6 17.9 13.00 11.00
YHJD30S41S7 FC/MC/PC32 14.5 800 - 1200
1000 29.4 22.0 13.00 11.00
YHJD30S41S7 FC/MC/PC35
17.5, 21.0
800 - 1200
1000 29.4 22.0 13.00 11.00
YHJD30S41S7 FC/MC/PC37 14.5 800 - 1200
1000 29.4 22.4 13.00 11.00
YHJD30S41S7 FC/MC/PC43
17.5, 21.0
800 - 1200
1000 29.4 22.4 13.00 11.00
YHJD36S41S7 FC/MC/PC37 14.5 1000 - 1400
1200 35.4 27.4 13.00 11.00
YHJD36S41S7 FC/MC/PC43
17.5, 21.0
1000 - 1400
1200 35.4 27.4 13.00 11.00
YHJD36S41S7 FC/MC/PC48
21.0, 24.5
1000 - 1400
1200 35.4 27.6 13.00 11.00
YHJD42S41S7 FC/MC/PC48
21.0, 24.5
1200 - 1600
1400 40.5 31.6 13.00 11.00
YHJD42S41S7 FC/MC/PC60
21.0, 24.5
1200 - 1600
1400 40.5 31.8 13.00 11.00
YHJD48S41S7 FC/MC/PC60
21.0, 24.5
1400 - 1800
1600 45.0 32.4 13.00 11.00
YHJD48S41S7 FC/MC62D 24.5 1400 - 1800
1600 45.0 33.2 13.00 11.00
YHJD60S41S7 FC/MC62D 24.5 1600 - 2000
1800 56.0 42.5 13.00 11.00
YHJD60S41S7 FC64D 24.5 1600 - 2000
1800 56.0 43.0 13.00 11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
571209-YTG-F-0615