Johnson Controls Unitary Products 19
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE
MODEL
COIL
1
MODEL
HEATING
2
47°F 17°F HSPF
MBH COP KW MBH COP KW STD
14 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
3
YHJD48S41S7
Y*(8,L)C*C20
FC/PC60C 46.0 3.60 3.74 24.2 2.42 2.93 8.20
YHJD48S41S7 Y*9C*D20 FC/MC62D 45.0 3.34 3.95 24.8 2.42 3.00 8.20
YHJD60S41S7
T*(8,L)V*C20
FC/MC62D 57.0 3.60 4.64 37.8 2.42 4.58 8.20
YHJD60S41S7
T*(8,L)V*C20
FC64D 57.0 3.82 4.37 38.5 2.50 4.51 8.20
YHJD60S41S7 T*9V*C20 FC/MC62D 57.0 3.58 4.67 38.0 2.42 4.60 8.20
YHJD60S41S7 T*9V*C20 FC64D 57.0 3.70 4.51 38.0 2.46 4.53 8.20
YHJD60S41S7 T*9V*D20 FC/MC62D 57.0 3.60 4.64 37.8 2.44 4.54 8.20
YHJD60S41S7 T*9V*D20 FC64D 57.0 3.72 4.49 37.8 2.48 4.47 8.20
YHJD60S41S7 TM8X100C20MP11 FC/MC62D 57.0 3.64 4.59 37.6 2.46 4.48 8.20
YHJD60S41S7 TM8X100C20MP11 FC64D 57.0 3.72 4.49 37.4 2.48 4.42 8.20
YHJD60S41S7 TM8X120C20MP11 FC/MC62D 57.0 3.64 4.59 37.6 2.46 4.48 8.20
YHJD60S41S7 TM8X120C20MP11 FC64D 57.0 3.72 4.49 37.4 2.48 4.42 8.20
YHJD60S41S7 TM9E100C20MP11 FC/MC62D 57.0 3.56 4.69 37.6 2.40 4.59 8.20
YHJD60S41S7 TM9E100C20MP11 FC64D 57.0 3.66 4.56 37.8 2.46 4.50 8.20
YHJD60S41S7 TM9E120D20MP11 FC/MC62D 57.0 3.56 4.69 37.6 2.42 4.55 8.20
YHJD60S41S7 TM9E120D20MP11 FC64D 57.0 3.64 4.59 37.6 2.46 4.48 8.20
YHJD60S41S7 TMLX100C20MP11 FC/MC62D 57.0 3.64 4.59 37.6 2.46 4.48 8.20
YHJD60S41S7 TMLX100C20MP11 FC64D 57.0 3.72 4.49 37.4 2.48 4.42 8.20
YHJD60S41S7 TMLX120C20MP11 FC/MC62D 57.0 3.64 4.59 37.6 2.46 4.48 8.20
YHJD60S41S7 TMLX120C20MP11 FC64D 57.0 3.72 4.49 37.4 2.48 4.42 8.20
YHJD60S41S7
Y*(8,L)C*C20
FC/MC62D 57.0 3.60 4.64 37.8 2.42 4.58 8.20
YHJD60S41S7
Y*(8,L)C*C20
FC64D 57.0 3.82 4.37 38.5 2.50 4.51 8.20
YHJD60S41S7 Y*9C*C20 FC/MC62D 57.0 3.58 4.67 38.0 2.42 4.60 8.20
YHJD60S41S7 Y*9C*C20 FC64D 57.0 3.70 4.51 38.0 2.46 4.53 8.20
YHJD60S41S7 Y*9C*D20 FC/MC62D 57.0 3.60 4.64 37.8 2.44 4.54 8.20
YHJD60S41S7 Y*9C*D20 FC64D 57.0 3.72 4.49 37.8 2.48 4.47 8.20
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
3. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
— = Not Applicable.
571209-YTG-F-0615