32 Johnson Controls Unitary Products
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YHJD48S41S7
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
IDCFM 1400 1600 1800
ID DB (°F)
80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F)
57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 43.3 48.2 47.9 52.1 57.3 46.0 49.5 49.5 54.2 59.4 48.6 50.8 51.1 56.4 61.5
S.C. 42.6 38.3 33.1 32.6 27.0 45.2 41.3 35.4 35.0 28.4 47.8 44.3 37.7 37.4 29.8
KW 2.46 2.49 2.48 2.51 2.53 2.55 2.56 2.57 2.59 2.61 2.64 2.63 2.66 2.68 2.69
75
T.C. 41.9 45.9 45.8 49.9 55.0 44.4 47.2 47.2 51.8 56.8 46.8 48.5 48.7 53.6 58.6
S.C. 41.2 37.3 32.0 31.6 26.0 43.6 40.3 34.3 33.9 27.4 46.0 43.3 36.6 36.3 28.8
KW 2.79 2.82 2.81 2.84 2.87 2.88 2.89 2.90 2.93 2.95 2.97 2.97 2.99 3.01 3.03
85
T.C. 40.6 43.7 43.6 47.8 52.6 42.8 44.9 44.9 49.4 54.2 45.0 46.1 46.2 50.9 55.8
S.C. 39.9 36.2 31.0 30.7 25.0 42.0 39.3 33.3 32.9 26.3 44.2 42.3 35.5 35.2 27.7
KW 3.12 3.15 3.14 3.18 3.21 3.21 3.22 3.23 3.26 3.29 3.31 3.30 3.32 3.34 3.38
95
T.C. 39.2 41.4 41.4 45.6 50.3 41.2 42.6 42.6 46.9 51.6 43.1 43.7 43.8 48.2 52.9
S.C. 38.6 35.2 30.0 29.7 24.1 40.5 38.2 32.2 31.9 25.3 42.4 41.3 34.5 34.1 26.6
KW 3.46 3.48 3.48 3.52 3.55 3.55 3.55 3.56 3.60 3.64 3.64 3.63 3.65 3.68 3.72
105
T.C. 37.2 38.8 38.9 42.8 47.2 39.1 39.8 39.9 44.0 48.3 40.9 40.8 40.9 45.1 49.5
S.C. 36.6 34.0 28.8 28.5 22.9 38.4 36.7 31.0 30.7 24.1 40.2 39.3 33.2 32.8 25.3
KW 3.90 3.92 3.92 3.96 4.01 3.99 4.00 4.00 4.04 4.09 4.08 4.07 4.08 4.12 4.17
115
T.C. 35.2 36.2 36.4 40.0 44.2 36.9 37.1 37.2 41.0 45.1 38.7 37.9 38.1 42.0 46.1
S.C. 34.6 32.9 27.7 27.4 21.8 36.3 35.1 29.9 29.5 22.9 38.0 37.3 32.0 31.6 24.1
KW 4.34 4.35 4.36 4.40 4.46 4.44 4.44 4.44 4.48 4.54 4.53 4.52 4.52 4.57 4.62
125
T.C. 33.2 33.6 33.8 37.3 41.1 34.8 34.3 34.5 38.1 41.9 36.5 35.0 35.2 38.9 42.7
S.C. 32.6 31.8 26.6 26.2 20.6 34.2 33.5 28.7 28.2 21.7 35.9 35.0 30.8 30.3 22.9
KW 4.79 4.79 4.79 4.84 4.91 4.88 4.88 4.88 4.93 4.99 4.97 4.96 4.96 5.02 5.06
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Green shaded cells are ACCA (TVA) conditions. Blue shaded cells are AHRI conditions.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Some of the combinations shown in these multiplier tables are not valid for use in the U.S.A. Please see the Capacity
Tables in the front of this Technical Guide for US matches, and verify matchups in the online AHRI directory at
www.ahridirectory.org before sale. The matches shown at the end of this Technical Guide are for use in Canda Only.
Air Handlers Coils T.C. S.C. KW
FC/MC/PC60 0.98 1.02 1.16
FC/MC62D 0.98 1.04 1.16
AHE48D
1.02 1.10 1.11
AHE60D
1.02 1.12 1.11
AHV48D
0.99 1.02 1.08
AHV60D
1.00 1.05 1.09
MV16C FC60C 1.00 1.10 1.09
Air Handlers Coils T.C. S.C. KW
MV20D FC/MC60D 1.00 1.05 1.09
MV20D FC/MC62D 1.01 1.04 1.10
MX16CN21 FC60C 1.00 1.04 1.11
MX20DN21 FC/MC60D 1.01 1.04 1.10
MX20DN21 FC/MC62D 1.01 1.07 1.10
571209-YTG-F-0615