Johnson Controls Unitary Products 13
HEATING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR
HANDLER
COIL
1
MODEL
HEATING
2
47°F 17°F HSPF
MBH COP KW MBH COP KW STD
14 SEER HP WITH AIR HANDLERS
YHJD42S41S7 MX20DN21 FC/MC48D 38.0 3.84 2.90 20.2 2.50 2.37 8.20
YHJD42S41S7 MX20DN21 FC/MC60D 39.5 3.92 2.95 21.2 2.52 2.46 8.20
YHJD48S41S7 AHE48D
–
46.0 3.60 3.74 24.8 2.44 2.98 8.20
YHJD48S41S7 AHE60D
–
45.0 3.46 3.81 24.8 2.48 2.93 8.20
YHJD48S41S7 AHV48D
–
46.0 3.60 3.74 24.0 2.44 2.88 8.20
YHJD48S41S7 AHV60D
–
45.0 3.36 3.92 24.4 2.46 2.91 8.20
YHJD48S41S7 MV16C FC60C 46.0 3.60 3.74 24.2 2.42 2.93 8.20
YHJD48S41S7 MV20D FC/MC60D 46.0 3.60 3.74 24.2 2.44 2.91 8.20
YHJD48S41S7 MV20D FC/MC62D 45.0 3.40 3.88 24.4 2.48 2.88 8.20
YHJD48S41S7 MX16CN21 FC60C 46.0 3.60 3.74 24.4 2.40 2.98 8.20
YHJD48S41S7 MX20DN21 FC/MC60D 46.0 3.60 3.74 24.0 2.46 2.86 8.20
YHJD48S41S7 MX20DN21 FC/MC62D 45.0 3.42 3.86 24.4 2.52 2.84 8.20
YHJD60S41S7 AHE60D
–
57.0 3.76 4.44 37.8 2.50 4.43 8.20
YHJD60S41S7 AHV60D
–
57.0 3.64 4.59 37.6 2.46 4.48 8.20
YHJD60S41S7 MV20D FC/MC62D 57.0 3.74 4.47 38.0 2.48 4.49 8.20
YHJD60S41S7 MV20D FC64D 57.0 3.84 4.35 38.5 2.54 4.44 8.20
YHJD60S41S7 MX20DN21 FC/MC62D 57.0 3.76 4.44 37.4 2.52 4.35 8.20
YHJD60S41S7 MX20DN21 FC64D 57.0 3.88 4.30 37.6 2.56 4.30 8.20
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input dur-
ing the same period.
MA Modular Air Handlers use Coil Only Ratings.
— = Not Applicable.
571209-YTG-F-0615