Johnson Controls Unitary Products
5
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
14 SEER HP WITH AIR HANDLERS
YHJD42S41S7 MX20DN21 24.5 FC/MC48D 1375 41.5 31.6 14.00 12.00
YHJD42S41S7 MX20DN21 24.5 FC/MC60D 1375 40.5 31.8 14.00 12.00
YHJD48S41S7 AHE48D 24.5
–
1600 46.0 35.2 14.00 12.00
YHJD48S41S7 AHE60D 24.5
–
1550 48.0 35.6 14.00 12.00
YHJD48S41S7 AHV48D 24.5
–
1300 46.0 32.4 14.00 12.00
YHJD48S41S7 AHV60D 24.5
–
1340 47.0 33.4 14.00 12.00
YHJD48S41S7 MV16C 21.0 FC60C 1400 46.0 35.0 14.00 12.00
YHJD48S41S7 MV20D 24.5 FC/MC60D 1400 46.0 33.4 14.00 12.00
YHJD48S41S7 MV20D 24.5 FC/MC62D 1400 47.5 33.2 14.00 12.00
YHJD48S41S7 MX16CN21 21.0 FC60C 1400 46.0 33.2 14.00 11.75
YHJD48S41S7 MX20DN21 24.5 FC/MC60D 1375 46.0 33.2 14.00 12.00
YHJD48S41S7 MX20DN21 24.5 FC/MC62D 1400 47.5 34.0 14.00 12.00
YHJD60S41S7 AHE60D 24.5
–
1835 57.0 42.5 14.00 12.00
YHJD60S41S7 AHV60D 24.5
–
1635 57.0 40.5 14.00 12.00
YHJD60S41S7 MV20D 24.5 FC/MC62D 1855 57.0 42.5 14.00 12.00
YHJD60S41S7 MV20D 24.5 FC64D 1855 57.0 42.0 14.00 12.00
YHJD60S41S7 MX20DN21 24.5 FC/MC62D 1750 57.0 43.5 14.00 12.00
YHJD60S41S7 MX20DN21 24.5 FC64D 1750 57.0 43.0 14.00 12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at
those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the to-
tal electric power input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
571209-YTG-F-0615