561923-YTG-E-0613
Johnson Controls Unitary Products 23
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. YHJF18S41S1
INDOOR COIL MODEL NO. AHX30
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 400 600 800
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C.
17.2 18.8 18.8 20.5 22.2 19.2 19.9 20.1 21.7 22.9 21.2 20.9 21.3 22.8 23.6
S.C.
16.8 14.9 12.9 12.9 11.0 18.8 17.7 15.2 14.7 11.7 20.8 20.5 17.4 16.5 12.5
KW
0.86 0.89 0.89 0.88 0.88 0.94 0.96 0.96 0.95 0.95 1.02 1.02 1.02 1.02 1.02
75
T.C.
16.4 17.9 17.9 19.7 21.3 18.4 19.1 19.0 20.8 22.1 20.4 20.2 20.2 21.8 22.9
S.C.
16.1 14.5 12.5 12.5 10.5 18.0 17.1 14.8 14.4 11.5 20.0 19.8 17.0 16.3 12.4
KW
0.99 1.02 1.02 1.02 1.02 1.08 1.09 1.09 1.09 1.10 1.17 1.16 1.17 1.17 1.18
85
T.C.
15.7 17.0 17.0 18.9 20.4 17.7 18.3 18.0 19.9 21.3 19.6 19.5 19.1 20.8 22.1
S.C.
15.4 14.1 12.1 12.1 10.1 17.3 16.6 14.3 14.2 11.2 19.2 19.1 16.6 16.2 12.2
KW
1.12 1.14 1.14 1.15 1.17 1.22 1.23 1.22 1.24 1.25 1.31 1.31 1.31 1.32 1.33
95
T.C.
15.0 16.1 16.1 18.1 19.6 16.9 17.4 17.0 19.0 20.4 18.8 18.8 18.0 19.8 21.3
S.C.
14.7 13.7 11.6 11.8 9.7 16.5 16.0 13.9 13.9 10.9 18.4 18.4 16.2 16.0 12.1
KW
1.25 1.26 1.26 1.29 1.31 1.36 1.36 1.36 1.38 1.40 1.46 1.46 1.45 1.46 1.49
105
T.C.
14.0 14.7 14.8 16.7 18.4 15.9 16.2 15.7 17.6 19.2 17.7 17.7 16.6 18.5 20.1
S.C.
13.7 13.1 11.0 11.2 9.2 15.5 15.2 13.3 13.4 10.4 17.3 17.3 15.6 15.6 11.6
KW
1.41 1.42 1.42 1.45 1.48 1.52 1.52 1.51 1.54 1.57 1.63 1.63 1.61 1.63 1.65
115
T.C.
13.1 13.4 13.4 15.4 17.2 14.8 15.0 14.4 16.2 18.0 16.6 16.6 15.3 17.1 18.8
S.C.
12.8 12.5 10.5 10.6 8.7 14.5 14.4 12.7 12.9 9.9 16.2 16.2 15.0 15.1 11.2
KW
1.56 1.57 1.57 1.60 1.65 1.68 1.68 1.67 1.70 1.74 1.80 1.80 1.77 1.80 1.82
125
T.C.
12.2 12.1 12.1 14.0 16.1 13.8 13.8 13.0 14.9 16.8 15.5 15.5 14.0 15.7 17.5
S.C.
11.9 11.9 9.9 10.1 8.2 13.5 13.5 12.1 12.3 9.5 15.1 15.1 14.0 14.6 10.7
KW
1.72 1.72 1.72 1.76 1.82 1.84 1.84 1.82 1.87 1.90 1.97 1.97 1.92 1.97 1.99
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Air Handler Coil T.C. S.C. KW
FC/MC/PC32 0.96 0.94 1.11
FC/MC/PC35 0.96 0.94 1.11
FC/MC/PC37 0.96 0.95 1.11
FC/MC/PC43 0.96 0.95 1.11
AHE24B 0.98 0.96 1.00
AHE30B 0.98 0.96 1.01
AHR24B 0.96 0.94 1.11
AHV24B 0.98 0.96 1.01
AHV30B 1.01 1.05 1.04
AHV36C 1.01 1.04 1.02
AV*36 1.00 1.01 1.00
MV12B FC/MC35B 0.98 0.96 1.02
MV12B FC/MC43B 0.98 0.97 1.02
MX12B FC/MC35B 1.01 1.03 0.99
MX12B FC/MC43B 0.99 0.98 1.00
Furnace Coil T.C. S.C. KW
T*(8,L)V*A12 FC/MC/PC32A
0.98 0.96 1.02
T*(8,L)V*A12 FC/MC/PC37A
0.99 1.01 1.02
T*(8,L)V*B12 FC/MC/PC35B
0.99 0.99 1.02
T*(8,L)V*B12 FC/MC/PC43B
0.97 0.96 1.01
T*(8,L)V*C16 FC/MC/PC35C
0.99 1.01 1.01
T*(8,L)X*A12 FC/MC/PC32A
0.98 0.97 0.99
T*9V*A10 FC/MC/PC32A
0.98 0.96 1.03
T*9V*A10 FC/MC/PC37A
0.97 0.95 1.03
T*9(C,V)*B12 FC/MC/PC35B
0.97 0.95 1.01
T*9(C,V)*C16 FC/MC/PC35C
0.99 1.01 1.01
T*9X*A10 FC/MC/PC32A
0.98 0.96 1.02
T*9X*A10 FC/MC/PC37A
0.98 0.97 1.02
Y*(8,L)C*A12 FC/MC/PC32A
0.98 0.96 1.02
Y*(8,L)C*A12 FC/MC/PC37A
0.99 1.01 1.02
Y*(8,L)C*B12 FC/MC/PC35B
0.99 0.99 1.02
Y*(8,L)C*B12 FC/MC/PC43B
0.97 0.96 1.01
Y*(8,L)C*C16 FC/MC/PC35C
0.99 1.01 1.01
Y*9C*B12 FC/MC/PC35B
0.97 0.95 1.01
Y*9C*C16 FC/MC/PC35C
0.99 1.01 1.01