EasyManua.ls Logo

York YHJF18 - Page 39

York YHJF18
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
561923-YTG-E-0613
Johnson Controls Unitary Products 39
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YHJF48S41S1
EVAPORATOR COIL MODEL NO F6FP060
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1400 1600 1800
MBH COP KW MBH COP KW MBH COP KW
60
60 60.5 5.2 3.41 61.2 4.9 3.64 61.9 4.7 3.88
70 59.2 4.5 3.87 59.8 4.3 4.08 60.4 4.1 4.29
80 57.9 3.9 4.33 58.4 3.8 4.51 58.9 3.7 4.69
47
60 51.6 4.3 3.48 51.8 4.1 3.70 52.0 3.9 3.92
70 50.5 3.8 3.92 50.7 3.8 3.88 51.0 3.9 3.85
80 49.4 3.3 4.34 49.7 3.1 4.68 50.0 2.9 5.02
40
60 46.4 3.9 3.50 46.6 3.7 3.73 46.8 3.5 3.96
70 45.7 3.4 4.00 45.8 3.2 4.23 45.8 3.0 4.47
80 45.0 2.9 4.50 44.9 2.8 4.74 44.9 2.6 4.98
30
60 38.7 3.4 3.31 39.0 3.2 3.59 39.4 3.0 3.88
70 37.6 3.2 3.48 38.1 2.9 3.87 38.6 2.7 4.25
80 36.4 2.9 3.65 37.2 2.6 4.14 37.9 2.4 4.62
17
60 28.9 3.2 2.66 30.2 3.0 2.93 31.6 2.9 3.20
70 31.2 2.6 3.52 32.2 2.6 3.59 33.2 2.7 3.66
80 29.6 2.3 3.71 30.2 2.3 3.80 30.8 2.3 3.89
10
60 27.3 2.6 3.05 27.0 2.5 3.14 26.7 2.4 3.23
70 26.5 2.3 3.36 27.5 2.2 3.67 28.5 2.1 3.99
80 25.7 2.1 3.66 28.0 2.0 4.21 30.4 1.9 4.75
NOTE: ALL CAPACITIES ARE NET, WITH INDOOR FAN HEAT ALREADY DEDUCTED. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Air Handler Coil MBH COP KW
FC/MC62 1.02 0.95 1.07
AHE60D 1.00 1.00 1.00
AHR60D 1.02 0.97 1.05
AHV60D 1.01 0.98 1.03
MV20D FC/MC62D 1.01 0.99 1.02
MV20D FC64D 1.01 1.03 0.98
MX20D FC/MC62D 1.00 1.01 1.00
MX20D FC64D 1.01 1.05 0.97
Furnace Coil MBH COP KW
T*(8,L)V*C16 FC/MC62D 1.01 0.97 1.05
T*(8,L)V*C16 FC64D 1.02 1.01 1.02
T*(8,L)V*C20 FC/MC62D 1.01 0.98 1.04
T*(8,L)V*C20 FC64D 1.02 1.02 1.01
T*(8,L)X*C16 FC/MC62D 1.01 0.98 1.04
T*(8,L)X*C16 FC64D 1.02 1.02 1.01
T*(8,L)X*C20 FC/MC62D 1.01 1.01 1.00
T*(8,L)X*C20 FC64D 1.01 1.03 0.99
T*9(C,V)*C16 FC/MC62D 1.02 0.97 1.06
T*9(C,V)*C16 FC64D 1.02 1.01 1.02
T*9(C,V)*C20 FC/MC62D 1.02 0.98 1.05
T*9(C,V)*C20 FC64D 1.03 0.99 1.04
T*9(C,V)*D20 FC/MC62D 1.02 0.96 1.06
T*9(C,V)*D20 FC64D 1.02 1.00 1.02
T*9X*C16 FC/MC62D 1.01 0.98 1.04
T*9X*C16 FC64D 1.02 1.02 1.01
T*9X*C20 FC/MC62D 1.01 0.98 1.03
T*9X*C20 FC64D 1.02 1.02 1.00
T*9X*D20 FC/MC62D 1.01 0.97 1.04
T*9X*D20 FC64D 1.02 1.01 1.01
Y*(8,L)C*C16 FC/MC62D 1.01 0.97 1.05
Y*(8,L)C*C16 FC64D 1.02 1.01 1.02
Y*(8,L)C*C20 FC/MC62D 1.01 0.98 1.04
Y*(8,L)C*C20 FC64D 1.02 1.02 1.01
Y*9C*C16 FC/MC62D 1.02 0.97 1.06
Y*9C*C16 FC64D 1.02 1.01 1.02
Y*9C*C20 FC/MC62D 1.02 0.98 1.05
Y*9C*C20 FC64D 1.03 0.99 1.04
Y*9C*D20 FC/MC62D 1.02 0.96 1.06
Y*9C*D20 FC64D 1.02 1.00 1.02
Furnace Coil MBH COP KW