561923-YTG-E-0613
Johnson Controls Unitary Products 5
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
YHJF42S41S2
AHE42D 24.5 1385 40.5 30.2 15.00 12.50
AHE48D 24.5 1385 40.5 30.0 15.00 12.50
AHE60D 24.5 1390 40.0 30.8 15.00 12.50
AHR42C 21.0 1485 40.0 30.4 13.25 11.35
AHR48D 24.5 1320 39.0 28.4 13.25 11.35
AHR60D 24.5 1350 39.5 29.6 13.25 11.35
AHV48D 24.5 1155 39.5 29.2 14.50 12.50
AHV60D 24.5 1340 40.5 31.6 14.50 12.00
MV16C 21.0 FC/MC48C 1400 40.5 30.0 14.50 12.00
MV16C 21.0 FC60C 1400 40.5 30.2 14.50 12.00
MV20D 24.5 FC/MC48D 1470 41.0 31.0 15.00 12.50
MV20D 24.5 FC/MC60D 1400 40.5 30.2 15.00 12.50
MV20D 24.5 FC/MC62D 1400 40.5 31.2 15.00 12.50
MX16C 21.0 FC/MC48C 1390 40.5 30.2 15.00 12.50
MX16C 21.0 FC60C 1420 40.5 30.4 15.00 12.50
MX20D 24.5 FC/MC48D 1415 40.5 30.0 15.00 12.50
MX20D 24.5 FC/MC60D 1470 41.0 31.4 15.00 12.50
MX20D 24.5 FC/MC62D 1470 40.5 31.8 15.00 12.50
YHJF48S41S1
AHE60D 24.5 1565 47.0 35.4 15.00 12.50
AHR60D 24.5 1620 47.5 35.6 13.25 11.35
AHV60D 24.5 1570 47.5 34.8 14.50 12.50
MV20D 24.5 FC/MC62D 1630 48.0 36.2 15.00 12.50
MV20D 24.5 FC64D 1630 48.0 36.2 15.00 12.50
MX20D 24.5 FC/MC62D 1605 47.0 35.1 15.00 12.50
MX20D 24.5 FC64D 1605 47.0 35.7 15.00 12.50
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
STAGE
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
14.5 SEER HP WITH AIR HANDLERS
YHJF60S41S1
AHE60D 24.5
1 1160 46.0 29.8
15.00 12.20
2 1835 57.0 41.0
AHV60D 24.5
1 1090 46.5 30.8
15.00 11.75
2 1635 57.0 40.5
MV20D 24.5 FC/MC62D
1 1160 48.0 31.0
15.00 12.00
2 1855 57.0 40.5
MV20D 24.5 FC64D
1 1160 50.0 32.6
15.00 12.50
2 1855 59.0 42.5
MX20D 24.5 FC/MC62D
1 1390 48.0 32.4
15.00 12.50
2 1795 57.5 41.0
MX20D 24.5 FC64D
1 1390 49.5 33.8
15.00 12.50
2 1795 58.0 42.0
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80 °F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95 °F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
14.5 SEER HP WITH AIR HANDLERS