Johnson Controls Unitary Products 25
246750-YTG-M-0908
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
G*9V*C20 FC/MC/PC43C 21
1 780 23.6 - - 3.66
2 1200 33.2 20.6 8.40 3.70
2 780 29.3 19.0 8.10 3.35
G*9V*B12 FC/MC/PC43B 17
1 815 23.8 - - 3.60
2 1200 33.6 20.8 8.20 3.62
2 815 29.4 19.0 7.90 3.33
G*9V*C20 FC/MC/PC48C 21
1 745 23.6 - - 3.54
2 1330 33.6 20.8 8.30 3.70
2 745 29.1 19.3 7.80 3.24
G*9V*C16 FC/MC/PC48C 21
1 780 23.6 - - 3.60
2 1195 33.2 20.6 8.40 3.66
2 780 29.2 19.4 8.00 3.30
G*9V*C16 HC42 21
1 815 23.8 - - 3.60
2 1240 33.4 21.0 8.30 3.62
2 815 29.3 18.8 8.00 3.31
G*9V*C20 HC42 21
1 780 23.8 - - 3.64
2 1200 33.2 21.0 8.40 3.68
2 780 29.3 18.7 8.10 3.33
G*9V*B12 HD48 17
1 710 22.8 - - 2.96
2 1150 32.6 20.8 8.00 3.22
2 710 28.0 18.3 7.90 2.65
G*9V*C16 HD48 21
1 780 22.8 - - 3.16
2 1195 32.4 20.4 8.20 3.32
2 780 28.3 18.3 8.10 2.83
G*9V*C20 HD48 21
1 745 22.8 - - 3.02
2 1325 33.0 21.0 8.10 3.38
2 745 27.9 18.4 8.00 2.71
G*9V*A12 UC36A 14
1 780 23.8 - - 3.40
2 1200 33.2 20.8 8.00 3.40
2 780 29.1 19.6 7.80 3.16
G*9V*B12 UC36B 17
1 800 23.6 - - 3.44
2 1165 32.8 20.6 8.20 3.44
2 800 29.2 19.5 7.90 3.20
G*9V*C16 UC36C 21
1 915 23.8 - - 3.50
2 1185 32.8 20.4 8.30 3.50
2 915 29.5 19.6 8.00 3.33
G*9V*C20 UC36C 21
1 760 23.6 - - 3.44
2 1285 33.2 20.8 8.20 3.52
2 760 29.0 19.3 7.80 3.17
G*9V*C16 UC48C 21
1 780 24.4 - - 3.80
2 1195 33.4 20.8 8.50 3.80
2 780 29.6 19.0 8.20 3.51
G*9V*C20 UC48C 21
1 755 24.4 - - 3.74
2 1315 33.8 21.0 8.40 3.78
2 755 31.9 19.6 8.10 3.54
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - YZE03611With Variable Speed Furnaces (Continued)
VARIABLE SPEED
FURNACE MODEL
COIL
MODEL
1
W
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @
47
47 OD 17 OD
13 SEER HP WITH VARIABLE SPEED FURNACES
3