14 Johnson Controls Unitary Products
632151-YTG-A-1010
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
ACCESSORIES*
TXV Kits - 1TVM9 series thermal expansion valves precisely
meter refrigerant for optimum performance.
Bonnet Sensor (2SB13700124) - The bonnet sensor is used to
sense plenum temperature, and is optional with a gas or oil
back-up heat source. Compatible only with 13 SEER and higher
heat pumps.
Dehumidistat (2HU16700124) - Provides increased dehumidi-
fication when matched with variable speed furnace or air han-
dler.
Heat Pump Risers - (526-35389-000, 526-35390-000, 526-
35391-000) - 3", 6", or 12" risers mount easily in composite
base pan recesses, ensuring the unit stays clear of snow and
ice build-up in harsh winter weather.
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.
SOUND POWER RATINGS*
* Rated in accordance with ARI 270-95 Standards.
YZF06013(C)
(Y*(8,L)C/T*8V)*C20 FC64D
1 1060 42.5 3.48
2 1630 58.0 38.5 9.00 3.78
2 1060 58.0 39.0 9.00 3.30
(Y*9C/T*9V)*C16 FC64D
1 1040 42.5 3.46
2 1590 58.0 38.5 9.00 3.74
2 1040 58.0 39.0 9.00 3.28
(Y*9C/T*9V)*C20 FC64D
1 1040 42.5 3.46
2 1655 58.0 39.0 9.00 3.72
2 1040 58.0 39.0 9.00 3.28
(Y*9C/T*9V)*D20 FC64D
1 1085 42.5 3.46
2 1630 58.0 38.5 9.00 3.74
2 1085 58.0 39.0 9.00 3.28
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no sup-
plemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE MODEL
COIL
MODEL
1
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF
COP @
47
47 OD 17 OD
1 PH HP WITH HIGH EFFICIENCY FURNACES
3
UNIT MODEL
(dBA)
Cooling Heating
024 71.0 71.5
030 71.2 70.8
036 71.5 68.1
042 71.4 69.8
048 71.3 71.5
060 69.8 71.8