Johnson Controls Unitary Products 17
632151-YTG-A-1010
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO. YZF03613(C)
INDOOR COIL MODEL NO. AHX42
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM 1000 1200 1400
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57
65
T.C. 34.1 36.2 36.4 39.6 43.0 36.1 37.4 37.5 40.8 44.1 38.1 38.5 38.5 42.0 45.3
S.C. 34.1 31.2 26.9 26.6 21.7 36.1 34.5 28.9 28.5 22.8 38.1 37.8 30.9 30.3 23.9
K.W. 1.93 1.93 1.94 1.94 1.95 2.01 2.02 2.02 2.03 2.04 2.10 2.10 2.10 2.13 2.12
75
T.C. 32.9 34.7 34.8 38.0 41.2 34.8 35.7 35.7 38.9 42.2 36.6 36.6 36.7 39.9 43.3
S.C. 32.9 30.5 26.1 25.8 21.0 34.8 33.4 28.1 27.7 22.1 36.6 36.3 30.1 29.6 23.1
K.W. 2.20 2.20 2.20 2.21 2.23 2.29 2.29 2.29 2.30 2.32 2.37 2.37 2.37 2.39 2.41
85
T.C. 31.8 33.1 33.2 36.3 39.4 33.5 34.0 34.0 37.1 40.3 35.2 34.8 34.8 37.8 41.2
S.C. 31.8 29.8 25.4 25.1 20.3 33.5 32.3 27.4 27.0 21.3 35.2 34.7 29.4 28.9 22.4
K.W. 2.47 2.47 2.47 2.49 2.51 2.56 2.56 2.56 2.57 2.60 2.65 2.64 2.65 2.65 2.69
95
T.C. 30.6 31.5 31.6 34.6 37.6 32.1 32.3 32.3 35.2 38.4 33.7 33.0 33.0 35.8 39.2
S.C. 30.6 29.1 24.6 24.3 19.6 32.1 31.1 26.6 26.2 20.6 33.7 33.0 28.7 28.2 21.6
K.W. 2.74 2.74 2.74 2.77 2.79 2.83 2.83 2.83 2.84 2.89 2.92 2.91 2.92 2.90 2.98
105
T.C. 29.0 29.3 29.6 32.4 35.3 30.4 30.4 30.1 32.9 35.9 31.7 31.4 30.6 33.4 36.5
S.C. 29.0 28.2 23.7 23.4 18.6 30.4 29.9 25.7 25.3 19.7 31.7 31.4 27.7 27.2 20.7
K.W. 3.06 3.05 3.07 3.05 3.07 3.13 3.12 3.15 3.12 3.16 3.20 3.20 3.23 3.20 3.25
115
T.C. 27.4 27.2 27.6 30.2 33.0 28.6 28.5 27.9 30.6 33.4 29.8 29.8 28.2 31.0 33.9
S.C. 27.4 27.2 22.8 22.5 17.6 28.6 28.5 24.8 24.4 18.7 29.8 29.8 26.7 26.3 19.7
K.W. 3.38 3.35 3.40 3.32 3.34 3.43 3.42 3.47 3.41 3.43 3.49 3.49 3.54 3.50 3.52
125
T.C. 25.9 25.0 25.6 28.0 30.7 26.9 26.6 25.7 28.4 30.9 27.9 28.2 25.8 28.7 31.2
S.C. 25.9 25.0 21.9 21.6 16.7 26.9 26.6 23.8 23.5 17.7 27.9 28.2 25.8 25.4 18.8
K.W. 3.70 3.65 3.73 3.60 3.62 3.73 3.71 3.79 3.70 3.70 3.77 3.77 3.85 3.79 3.79
NOTE:
ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
AHX48 – 1.01 1.03 1.08
AV*48 – 1.00 1.01 1.08
F6FP042 – 1.00 1.03 1.08
F6FP048 – 0.99 0.97 1.06
MV12D FC/MC48D 0.99 0.98 1.06
MV16C FC/MC48C 0.98 0.98 1.06
MV12D FC/MC60D 0.98 0.97 1.06
Furnace Coil
T.C. S.C. KW
T*(8,L)X*C16 FC/MC/PC48C 0.99 0.98 1.06
T*(8,L)X*C20 FC/MC/PC48C 1.01 1.02 1.08
T*9X*C16 FC/MC/PC48C 1.00 1.02 1.08
T*9X*C20 FC/MC/PC48C 0.98 0.98 1.06
T*9X*D20 FC/MC/PC48D 1.00 1.02 1.08
(Y*(8,L)C/T*8V)*C16 FC/MC/PC48C 0.98 0.98 1.06
(Y*(8,L)C/T*8V)*C20 FC/MC/PC48C 0.98 0.98 1.06
(Y*9C/T*9V)*D20 FC/MC/PC48D 0.99 1.01 1.07
T*(8,L)X*C16 FC/PC60C 0.99 0.98 1.06
T*(8,L)X*C20 FC/PC60C 1.01 1.03 1.08
T*9X*C16 FC/PC60C 1.01 1.04 1.08
T*9X*C20 FC/PC60C 1.00 1.02 1.08
T*9X*D20 FC/MC/PC60D 1.01 1.05 1.09
(Y*(8,L)C/T*8V)*C16 FC/PC60C 0.99 0.97 1.06
(Y*(8,L)C/T*8V)*C20 FC/PC60C 0.99 1.00 1.07
(Y*9C/T*9V)*D20 FC/MC/PC60D 0.99 1.00 1.07
T*(8,L)X*C16 UC48C 0.99 0.99 1.06
T*(8,L)X*C20 UC48C 0.99 1.02 1.07
T*9X*C16 UC48C 0.99 1.02 1.06
T*9X*C20 UC48C 0.98 0.98 1.06
T*9X*D20 UC48D 0.98 0.98 1.06
(Y*(8,L)C/T*8V)*C16 UC48C 0.98 0.98 1.06
(Y*(8,L)C/T*8V)*C20 UC48C 0.98 0.98 1.06
T*(8,L)X*C16 UC60C 0.98 0.98 1.06
T*(8,L)X*C20 UC60C 0.99 1.01 1.06
T*9X*C16 UC60C 0.99 1.02 1.06
T*9X*C20 UC60C 0.98 0.97 1.05
T*9X*D20 UC60D 0.99 1.02 1.07
(Y*(8,L)C/T*8V)*C16 UC60C 0.98 0.97 1.05
(Y*(8,L)C/T*8V)*C20 UC60C 0.98 0.97 1.05
Furnace Coil
T.C. S.C. KW