24 Johnson Controls Unitary Products
632151-YTG-A-1010
Multipliers for determining the performance with other indoor sections.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO. YZF03613(C)
INDOOR COIL MODEL NO. AHX42
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1000 1200 1400
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 44.7 3.64 3.1 44.9 3.96 2.9 45.0 4.35 2.7
70 43.8 3.20 3.5 44.1 3.48 3.3 44.3 3.83 3.0
80 42.9 2.83 3.9 43.3 3.10 3.6 43.7 3.41 3.4
47
60 38.5 3.35 2.8 38.4 3.63 2.7 38.3 3.96 2.5
70 37.7 2.95 3.2 37.8 3.19 3.0 37.9 3.47 2.8
80 36.9 2.62 3.6 37.2 2.83 3.4 37.4 3.09 3.2
40
60 34.7 3.10 2.8 34.7 3.34 2.6 34.8 3.63 2.4
70 34.1 2.74 3.1 34.3 2.96 2.9 34.5 3.22 2.8
80 33.5 2.44 3.5 33.8 2.65 3.3 34.1 2.89 3.1
30
60 30.5 2.87 2.6 30.6 3.08 2.5 30.6 3.33 2.3
70 29.8 2.51 3.0 30.0 2.70 2.8 30.1 2.91 2.7
80 29.1 2.22 3.3 29.4 2.39 3.2 29.7 2.58 3.0
17
60 24.6 1.96 3.2 24.9 2.31 2.7 25.1 2.82 2.2
70 24.1 1.91 3.2 24.4 2.17 2.8 24.8 2.50 2.5
80 23.5 1.87 3.2 24.0 2.04 3.0 24.4 2.24 2.8
10
60 21.8 2.31 2.2 21.2 2.38 2.2 20.6 2.45 2.1
70 21.3 2.04 2.5 21.0 2.17 2.4 20.6 2.32 2.2
80 20.8 1.82 2.8 20.7 1.99 2.6 20.6 2.19 2.4
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
MBH KW COP
AHX48 1.00 1.02 0.98
AV*48 1.01 1.05 0.96
F6FP042 1.01 1.02 1.00
F6FP048 1.00 1.03 0.97
MV12D FC/MC48D 0.99 1.00 1.00
MV16C FC/MC48C 1.00 0.98 1.02
MV12D FC/MC60D 1.01 1.03 0.98
Furnace Coil
MBH KW COP
T*(8,L)X*C16 FC/MC/PC48C 0.99 1.00 1.00
T*(8,L)X*C20 FC/MC/PC48C 1.00 1.01 0.99
T*9X*C16 FC/MC/PC48C 1.01 1.00 1.01
T*9X*C20 FC/MC/PC48C 1.00 0.98 1.02
T*9X*D20 FC/MC/PC48D 1.01 1.01 1.00
(Y*(8,L)C/T*8V)*C16 FC/MC/PC48C 1.00 0.98 1.03
(Y*(8,L)C/T*8V)*C20 FC/MC/PC48C 1.00 0.98 1.02
(Y*9C/T*9V)*D20 FC/MC/PC48D 1.01 0.99 1.02
T*(8,L)X*C16 FC/PC60C 1.00 1.04 0.96
T*(8,L)X*C20 FC/PC60C 1.01 1.06 0.96
T*9X*C16 FC/PC60C 1.02 1.05 0.97
T*9X*C20 FC/PC60C 1.01 1.05 0.97
T*9X*D20 FC/MC/PC60D 1.01 1.07 0.94
(Y*(8,L)C/T*8V)*C16 FC/PC60C 1.01 1.03 0.98
(Y*(8,L)C/T*8V)*C20 FC/PC60C 1.01 1.04 0.98
(Y*9C/T*9V)*D20 FC/MC/PC60D 1.02 1.03 0.99
T*(8,L)X*C16 UC48C 1.00 1.04 0.96
T*(8,L)X*C20 UC48C 1.01 1.04 0.97
T*9X*C16 UC48C 1.01 1.03 0.99
T*9X*C20 UC48C 1.01 1.02 0.99
T*9X*D20 UC48D 1.01 1.03 0.98
(Y*(8,L)C/T*8V)*C16 UC48C 1.01 1.02 0.99
(Y*(8,L)C/T*8V)*C20 UC48C 1.01 1.03 0.98
T*(8,L)X*C16 UC60C 1.00 1.04 0.96
T*(8,L)X*C20 UC60C 1.01 1.04 0.97
T*9X*C16 UC60C 1.01 1.04 0.98
T*9X*C20 UC60C 1.01 1.02 0.99
T*9X*D20 UC60D 1.01 1.06 0.95
(Y*(8,L)C/T*8V)*C16 UC60C 1.01 1.02 0.99
(Y*(8,L)C/T*8V)*C20 UC60C 1.01 1.02 0.99
Furnace Coil
MBH KW COP

Related product manuals