6021980-UIM-A-1120
4 Johnson Controls Ducted Systems
Nomenclature
Z T 078 CA2 A 1
A
1A A 1
Product Category
Z = A/C, Single Pkg., R-410A
E = VFD/VAV Std Static
G = VFD/VAV High Static
H = VFD/VAV w/Bypass Std Static
K = VFD/VAV w/Bypass High Static
P = VFD IntelliSpeed Std Static
R = VFD IntelliSpeed High Static
S = VFD w/Byp IntelliSp Std Static
U = VFD w/Byp IntelliSp Hi Static
Blower Option
Product Generation
1 = First Generation
2 = Second Generation
C = Cooling Only
E = Electric Heat
Heat Type
09 = 9 KW (078,090,102)
18 = 18 KW (078,090,102,120,150)
24 = 24 KW (078,090,102,120,150)
36 = 36 KW (078,090,102,120,150)
54 = 54 KW (120,150)
18 = 180 MBH Input
24 = 240 MBH Input
Heat Capacity
Nominal Cooling Capacity
078 = 6.5 Ton
090 = 7.5 Ton
102 = 8.5 Ton
120 = 10 Ton
150 = 12.5 Ton
Product Identifier
T = Pkg AC Ultra High Eff
Voltage
2 = 208/230-3-60
4 = 460-3-60
Additional Options
1 = STD Throwaway Filter
2 = 2" Pleated Filters (Merv 8)
3 = 4" Pleated Filters (Merv 13)
4 = Coil Guard (CG), STD Filter
5 = 2" Pleated Filter,CG
6 = 4" Pleated Filter,CG
A = Std Cabinet
E = SSD (SST Drain Pan)
R = Reverse Drain Pan
A = No Economizer
B = Economizer w/Barometric RLF
D = Economizer w/Power EXH
H = Motorized Damper
Outdoor Air Option
1 = No Service Options
2 = DSC (Disconnect Switch)
3 = NCO (Non-PWR Conv. Outlet)
4 = PCO (Powered Conv. Outlet)
5 = DSC,NCO
6 = DSC,PCO
A = No Sensors
B = PHM (Phase Monitor)
C = DFS (Dirty Filter Switch)
D = SSD (Supply Air Smoke DET)
E = RSD (Return Air Smoke DET)
F = PHM,DFS
G = PHM,SSD
H = PHM,RSD
J = DFS,SSD
K = DFS,RSD
L = SSD,RSD
M = PHM,DFS,SSD
N = PHM,DFS,RSD
P = PHM,SSD,RSD
Q = DFS,SSD,RSD
R = PHM,DFS,SSD,RSD
Refrigeration
A = Standard Refrigeration
B = ECC (E-Coat Cond Coil)
C = EEC (E-Coat Evap Coil)
E = REH (Reheat)
F = ECC, EEC
G = ECC, EEC, HGBP
H = ECC, EEC, REH
J = ECC, HGBP
L = ECC, REH
M = EEC, HGBP
P = EEC, REH
Service Options
A = Stand Alone Smart Equipment™
C = BACnet MSTP,Mdbs,N2 COM Card
D = CPC Control, DFS, APS
F = Fault Detection Diagnostics
G = Novar UCM Ctrl, DFS, APS
H = Hnywll Excel 10 CTRL,DFS,APS
M = Verasys Single Zone
N = Verasys Change Over Bypass
P = Verasys VAV
Q = Verasys Single Zone W/FDD
R = Verasys COBP W/FDD
T = Verasys VAV W/FDD
Controls Option
6.5-12.5 Ton Model Number Nomenclature
Two Stage Natural Gas Heat Option
N = 2 Stage Gas Aluminized Steel
S = 2 Stage Gas Stainless Steel
00
00 = Cooling Only
Gas MBH Input (Unit Size Allowed)
Electric Heat (Unit Size Allowed)
Sensors
A
Cabinet Options

Table of Contents