5167821-YTG-K-1118
Johnson Controls Ducted Systems 47
115°F 125°F
1000
77 34.9 3.1 25.6 14.2 10.6 - - - 30.5 3.4 28.1 14.8 9.5 - - -
72 30.8 3.1 26.2 20.5 15.9 11.3 - - 26.9 3.5 25.3 19.1 14.6 10.1 - -
67 26.8 3.1 26.8 26.8 21.2 16.6 12.0 - 23.3 3.5 23.3 23.3 19.7 15.1 10.6 -
62 26.7 3.1 26.7 26.7 22.2 17.6 13.0 8.5 24.2 3.4 24.2 24.2 20.4 15.9 11.4 6.9
1200
77 35.5 3.1 29.3 18.3 11.6 - - - 31.0 3.5 29.4 18.6 10.3 - - -
72 31.4 3.1 28.3 22.8 17.3 11.8 - - 27.4 3.5 26.6 21.2 15.8 10.4 - -
67 27.2 3.1 27.2 27.2 23.0 17.5 12.0 - 23.7 3.5 23.7 23.7 21.2 15.8 10.4 -
62 27.1 3.1 27.1 27.1 24.1 18.6 13.1 7.6 24.5 3.5 24.5 24.5 22.0 16.6 11.2 5.8
57 26.6 3.1 26.6 26.6 23.7 18.2 12.7 7.2 24.0 3.5 24.0 24.0 21.6 16.2 10.8 5.4
1400
77 36.0 3.1 32.9 22.4 12.5 - - - 31.5 3.5 30.7 22.4 11.0 - - -
72 31.9 3.1 30.3 25.1 18.7 12.2 - - 27.8 3.5 27.8 23.2 16.9 10.6 - -
67 27.7 3.1 27.7 27.7 24.8 18.4 12.0 - 24.1 3.5 24.1 24.1 22.8 16.5 10.2 -
62 27.5 3.1 27.5 27.5 26.0 19.6 13.2 6.8 24.9 3.5 24.9 24.9 23.7 17.4 11.1 4.8
57 27.0 3.1 27.0 27.0 25.6 19.2 12.8 6.4 24.4 3.5 24.4 24.4 23.2 16.9 10.6 4.3
1600
77 36.6 3.1 36.6 26.6 13.4 - - - 32.0 3.5 32.0 26.1 11.8 - - -
72 32.4 3.1 32.4 27.4 20.0 12.7 - - 28.3 3.5 28.3 25.3 18.1 10.9 - -
67 28.1 3.1 28.1 28.1 26.7 19.3 12.0 - 24.5 3.5 24.5 24.5 24.4 17.2 10.0 -
62 28.0 3.1 28.0 28.0 28.0 20.6 13.3 6.0 25.3 3.5 25.3 25.3 25.3 18.1 10.9 3.7
57 27.5 3.1 27.5 27.5 27.5 20.2 12.8 5.5 24.8 3.5 24.8 24.8 24.8 17.6 10.4 3.2
1800
72 33.0 3.1 33.0 29.1 21.0 12.8 - - 28.7 3.5 28.7 26.4 18.4 10.4 - -
67 28.6 3.1 28.6 28.6 27.9 19.8 11.6 - 24.8 3.5 24.8 24.8 24.8 16.8 8.8 -
62 28.5 3.1 28.5 28.5 28.5 20.3 12.2 4.0 25.7 3.5 25.7 25.7 25.7 17.7 9.7 1.7
57 28.0 3.1 28.0 28.0 28.0 19.8 11.7 3.5 25.1 3.5 25.1 25.1 25.1 17.2 9.2 1.2
2000
72 33.6 3.1 33.6 30.9 21.9 12.9 - - 29.1 3.5 29.1 27.4 18.6 9.9 - -
67 29.2 3.1 29.2 29.2 29.2 20.2 11.2 - 25.2 3.5 25.2 25.2 25.2 16.4 7.6 -
62 29.0 3.1 29.0 29.0 29.0 20.0 11.1 2.1 26.1 3.5 26.1 26.1 26.1 17.3 8.5 -
57 28.5 3.1 28.5 28.5 28.5 19.5 10.5 1.6 25.5 3.5 25.5 25.5 25.5 16.7 7.9 -
1. These capacities are gross ratings. For net capacity, deduct the air blower motor, MBh = 3.415 x kW. Refer to the appropriate blower
performance table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZT102 (8.5 ton) 1st stage cooling (continued)
Air on evaporator
coil
Temperature of air on condenser coil
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
Total
capacity
1
(MBh)
Total input
(kW)
2
Sensible capacity (MBh)
CFM
WB
(°F)
Return dry bulb (°F) Return dry bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65