The Zemits Abigon Pro is an ultimate body remodelling and slimming system that combines cavitation, radiofrequency (RF), infrared light, and vacuum technologies. It is designed for targeted fat and cellulite reduction, body tightening, body sculpting, and facial and décolleté skin firming.
Function Description
The Abigon Pro system utilizes several technologies to achieve its body sculpting and slimming goals:
-
Cavitation: This technology uses ultrasonic sound waves (1 MHz to 5 MHz) to create microscopic implosions that disrupt subcutaneous fat cells. The lower the megahertz, the stronger and more penetrative the treatment. The fat cell membranes cannot withstand the pressure and explode, releasing their liquid content. This liquid product is then metabolized and removed from the body through normal channels. Cavitation is primarily used for targeted fat and cellulite reduction.
-
Radiofrequency (RF): RF energy heats the dermis and subcutaneous layer simultaneously, causing collagen fibers to contract, which leads to an immediate skin tightening effect. It also stimulates fibroblasts to produce new collagen and elastin fibers, resulting in long-term skin firming, reduced wrinkle depth, and improved contour. RF is also effective in stimulating and damaging adipocytes (fat cells) to release fat into the bloodstream. The Abigon Pro includes Multipolar RF for body tightening, Bipolar RF for facial and targeted facial skin firming, and Tripolar RF for all-over face and décolleté skin firming.
-
Vacuum + RF + InfraRed Light (Supreme Body Sculpting Slimming Applicator): This unique handpiece combines vacuum suction, RF, and infrared light for comprehensive body contouring and sculpting.
- Vacuum Lymphatic Drainage: Vacuum suction lifts body tissues, similar to a massage, to stimulate the lymphatic and circulatory systems. This aids in the flow of waste products and tissue fluids to the nearest lymph nodes, improving poor blood circulation, lymphatic circulation, and reducing fluid retention or edema. It also assists in removing fatty deposits.
- Infrared Light Skin Tightening: Infrared light improves skin imperfections, reduces sagging skin, lack of skin tone, and laxity. It heats and contracts collagen fibers, stimulating the formation of new collagen.
- The synergy of vacuum suction with RF and IR Light helps to smooth and tighten the skin, flush toxins and waste products with natural lymph flow, decrease cellulite, and drastically improve skin elasticity.
Important Technical Specifications
- Voltage: 110-220 V B/50-60 HZ
- Power Supply: ≤180 W
- Ultrasound Cavitation Frequency: 40kHz
- Ultrasound Cavitation Power: 80W/cm²
- RF Frequency: 1 MHz
- RF Power: 150W
- Vacuum Aspiration: ≥80 kPa
Usage Features
The Abigon Pro system offers detailed configuration and protocols for each treatment type:
General Configuration:
- The system features a touch screen for easy navigation.
- Inputs for various applicators are located on the back: Cavitation, Bipolar RF, Tripolar RF, Vacuum RF, and Multipolar RF handpieces.
- A vacuum intensity adjuster is on the right side, and the power cord input and power button are on the left side.
Installation:
- Unpack the machine and place it on a steady surface.
- Attach acrylic holders for handpieces.
- Connect all handpieces to their specific inputs.
- Place handpieces on the acrylic holders.
- Install the vacuum filter to the back of the unit.
Working Screen & Handpiece Selection:
- Touch the screen to enter the working menu.
- Select the desired handpiece: Cavitation, Multipolar RF, Vacuum RF, Tripolar RF, or Bipolar RF.
Cavitation Treatment:
- Working Time: 20-40 minutes per session, not exceeding 60 minutes per body per week.
- Intensity: Adjustable from Level 1-10.
- Working Modes:
- P0 (Most Intense): Constant cavitation, ideal for buttocks, back, and outer thighs.
- P1 (Less Intense): Ideal for front and inner thighs.
- P2 (Medium Intensity): Ideal for abdomen and arms.
- P3 (Pulse Mode, Least Intensive): Ideal for target fat deposits.
- Protocol Steps:
- Position the client comfortably.
- Apply a thick, even layer of conductive gel (warm it up for comfort).
- Treat only areas with unwanted fatty layers.
- Perform slow, circular massage motions with the handpiece, directing it into the fatty fold while pushing the skin fold towards it.
- Reapply gel as needed to ensure smooth gliding.
- Treat for 20-30 minutes based on the area size and fat layer depth.
- On the lower abdomen, always point the handpiece into the fatty fold, not directly to the stomach cavity. Be gentle on the upper abdomen and avoid the rib cage.
- Wipe off excess gel.
- Follow with lymphatic drainage massage. For manual massage, apply a thin layer of massage oil and move in the direction of lymphatic flow.
- Recommendations: 1-2 sessions per week, 5-10 sessions in total. Drink 1.5-2 liters of water on treatment day. Avoid carbs 2 hours before/after. Engage in minimal physical activity.
Vacuum RF Treatment:
- Working Time: 20-30 minutes per session.
- RF Intensity: Adjustable from Level 1-20.
- Back of legs + buttocks: 12-18 RF for 30 minutes.
- Front surface of legs: 10-18 RF for 20 minutes.
- Abdomen: 12-18 RF for 15-20 minutes.
- Sides: 10-18 RF for 10 minutes.
- Hands: 10-15 RF for 20 minutes.
- Back: 12-18 RF for 15 minutes.
- Vacuum Suction Pattern: Adjust suction and release duration in seconds. Longer suction and shorter release lead to more intense treatment.
- Working Modes: P0 (buttocks/thighs), P1 (abdomen), P2 (back, flanks, waist), P3 (arms).
- Protocol: Start at low RF intensity, apply conductive gel, move handpiece in circular lines without pressure, point nozzle towards adipose tissue (avoid bones/cavities), keep handpiece in constant motion, apply only to fatty deposits, avoid protruding bones, joints, glands, face, neck, and armpits. Control gel layer. Provide lymphatic drainage after.
- Note: Adjust vacuum suction pattern gradually; higher RF intensity requires shorter vacuum inhale. All electrodes must contact the skin tightly to prevent burns. Higher intensity requires faster handpiece movement.
Body Multipolar RF Treatment:
- Working Time: 30-45 minutes per session.
- RF Intensity: Adjustable from Level 1-20.
- Back of legs + buttocks: 12-18 RF for 40 minutes.
- Front surface of legs: 10-18 RF for 30 minutes.
- Abdomen: 12-18 RF for 30-35 minutes.
- Sides: 10-18 RF for 20 minutes.
- Hands: 10-15 RF for 20-30 minutes.
Bipolar RF Treatment (Face):
- Working Time: Adjustable.
- RF Intensity: Adjustable from Level 1-20.
- Select for eyes and targeted facial treatments.
Tripolar RF Treatment (Face & Décolleté):
- Working Time: Adjustable.
- RF Intensity: Adjustable from Level 1-10.
- Select for all-over face and décolleté treatments.
RF Treatment General Notes (Bipolar & Tripolar):
- Duration: 20-50 minutes depending on area size and skin condition.
- Frequency: 5-15 sessions, 1-2 per week.
- Preparation: Remove all jewelry, cleanse skin, optional dermabrasion/skin peeling.
- Application: Apply conductive gel, start at low RF intensity, move handpiece slowly with circular motions, ensure all electrodes are in tight contact. Work in one area (half face, half neck, forehead) for 5-10 minutes.
- Finishing: Add LED, Ultrasound, or Cold therapy, then SPF and moisturizer.
- Important: Higher intensity requires faster handpiece movement. Client should feel a comfortable, deep warming.
Contraindications (Ultrasound Lipo-Cavitation and RF Treatment):
- Pregnant or breastfeeding
- Metallic implants (pins, prostheses, pacemakers)
- Intrauterine device (avoid abdomen)
- Epilepsy
- Cancer (any time, any form)
- Blood disorders
- Internal heat (fever, acute inflammation)
- Heart, kidney, and liver disease
- Severe high blood pressure or circulation problems
- Deep vein thrombosis, varicose veins
- Hemorrhagic disease, trauma, vascular rupture
- Inflammation of veins, phlebitis
- Current treatment with anticoagulants, anti-inflammatories, or antibiotics
- Long-term steroid use
- Infections
- Internal bleeding (ulcers)
- Autoimmune diseases
- Red, dry, itchy skin rashes
- Urinary incontinence
- Transmissible diseases
- Menstruation (avoid abdomen)
- Under 18 years of age
Maintenance Features
General Maintenance:
- Mandatory: Keep the external filter clean and dry, keep handpieces clean, disinfected, and dry, keep the screen clean and dry.
- The external filter is conveniently located on the back of the machine.
Filter Care, Removal & Replacement:
- Check and clean the filter after every procedure.
- If there is any oil inside the filter, detach it from the system and unscrew the top part counter-clockwise.
- Empty any waste content from the clear canister, wipe clean, pat dry, and attach it back together.
- Be careful not to lose the clear rubber seal inside the rim of the filter canister cover.
- Reinstall the filter to the back of the system.
- Ensure to plug the filter all the way in the backside of the system.
- Do not attempt to use the filter if it is not completely dry!
Filter Replacement:
- Even with routine washing, the filter will become clogged with waste materials, blocking off vacuum pressure. A decrease in performance will be noticed.
- Remove the old filter and dispose of it as required by local and federal laws.
- Install a new filter and replace the filter canister cover, ensuring the rubber seal is clean and in place.
Handpieces Cleaning and Sanitation:
- After every service, wipe clean from any remaining gel or oil.
- Spray with alcohol or wipe with alcohol tissues.
Screen Cleaning:
- If any fingerprints or gel residue are left, wipe clean using gentle cleansing wipes or pat dry.
- Use any brand of Pre-Moistened Electronic Wipes suitable for computers, monitors, and screens.
Power Supply:
- Do not use the system with extensions, as those might cause electrical damage.
- Use the system with a power surge.
Troubleshooting:
- Machine not turning on: Check power cable, power button, and fuse.
- Cavitation Handpiece not working: Ensure system is started, start button is on, and timer is running. To check, apply gel, place arm on surface, adjust intensity to moderate, and listen for a "buzzling noise" (cricket effect).
- RF Handpiece not working: Ensure system is started, start button is on, and timer is running. Ensure all electrodes touch the skin and the skin surface is not dry. Use enough gel. To check, apply gel to arm, place handpiece on skin, adjust intensity to moderate, move in small circles, and feel a light warm sensation. Gel helps current penetrate the dermis; dry/oily skin blocks it.