ELECTRICAL INSTALLATION
F 295 F 296
ELECTRICAL EQUIPMENT
Nominal voltage (minus
pole (-) grounded)
12 V
Battery (1)
Z 8621 - Z 10641
AKUMA 12V/135Ah
AKUMA 12V/165Ah
12 V
Z 11641
AKUMA 12V/165 Ah HD
AKUMA 12V/180 Ah
12 V
Alternator with voltage regulator (2)
Z 8621 - Z 10641
14V/70 A
Z 11641
6V/85 A
Starter motor (3)
12V/3,5kW
BASIC SERVICE INFORMATION
Battery "minus" pole must be ever connected with the ground and "plus" pole con-
nected with alternator. Vice versa connected battery destroys the complete electro-
nics of alternator. If starting the tractor by means of another battery or auxiliary
source dont forget to connect "plus" to "plus" and "minus" to "minus". Disconnect
battery by removing the connector from tractor ground (-) if changing any part of
charging circuit. Avoid possible short circuit on connectors.