82
HYDRAULIC SYSTEM
F_02_112 F_02_113 F_02_53
HYDRAULIC SYSTEM
The system consists of the inner and
outer circuit.
The source of pressurized oil is a gear
pump.
Oil is drawn from the common filling of
the gearbox and final drive housing.
HYDRAULIC PUMP
The hydraulic pump cannot be disen-
gaged. When the engine is running, the
pump is in operation.
Pump type Delivered quantity
2. UD 25.02 V 69 l/min
The pressure generated in the hydraulic
system by the hydraulic pump is limited
by a relief valve to 20 MPa.
LOCATION OF CONTROL ELEMENTS
- EHR - B - BOSCH ELECTRO-
HYDRAULIC SYSTEM
The control panel (1) is located on the
right fender.

Table of Contents