SECTION 4B - USER PROGRAMMING
Now we can signal pager number 0000134 by User numbers 19 (which will
receive Function beep alert 1), 29 (Function 2) and 39 (Function 3).
V
Validate (Y/N)? Yes
assigned to User 10 through User 39
This step was redundant if we were starting from initialized conditions
because all Users start out Validated.
F
Format (0-7)? 1
assigned to User 10 through User 39
M
Msgs: (Y) alpha (N) numeric (Y/N)? Yes
assigned to User 10 through User 39
P
Priority page (Y/N)? Yes
assigned to User 10 through User (CR)
P
Priority page (Y/N)? Yes
assigned to User 20 through User (CR)
P
Priority page (Y/N)? Yes
assigned to User 30 through User (CR)
The subscriber carrying pager 0000125 will receive pages immediately from
any of the 3 source functions (Users 10, 20, and 30).
Any of the operations above could have been performed in any order; none
are dependent on another one being programmed first.