EasyManua.ls Logo

ZIEHL-ABEGG AM-CAN-OPEN - MODBUS Register Description Excerpt

ZIEHL-ABEGG AM-CAN-OPEN
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.3 Excerpt from the MODBUS register description for ECblue Basic and Basic frequency
inverters I/Fcontrol
The examples listed here represent just a small selection of frequently used registers. The complete
MODBUS register description can be downloaded from our web site.
8.3.1 MODBUS Register overview
Holding Registers
MB Holding Register 1, Address: h0 = PIN input
MB Holding Register 2, Address: h1 = Control
MB Holding Register 3, Address: h2 = Speed control
MB Holding Register 4, Address: h3 = COM Parameter
MB Holding Register 5, Address: h4 = Controlmode
MB Holding Register 6, Address: h5 = Set Intern1
MB Holding Register 7, Address: h6 = Set Intern2: 1/min
MB Holding Register 8, Address: h7 = Min. Speed: 1/min
3)
MB Holding Register 9, Address: h8 = Max. Speed: 1/min
MB Holding Register 10, Address: h9 = Set Intern3: 1/min
MB Holding Register 11, Address: h10 = Inverting
MB Holding Register 12, Address: h11 = E11 Min
MB Holding Register 13, Address: h12 = E12 Max
MB Holding Register 14, Address: h13 = E1 Function
MB Holding Register 15, Address: h14 = D1 Function
MB Holding Register 16, Address: h15 = K1 Function
MB Holding Register 17, Address: h16 = Controller Setup Flags
MB Holding Register 18, Address: h17 = Communication Watchdog
MB Holding Register 19, Address: h18 = Limit
MB Holding Register 20, Address: h19 = Radio network code
MB Holding Register 26, Address: h25 = Ramp timing
MB Holding Register 31, Address: h30 = Suppression
MB Holding Register 32, Address: h31 = Range1 Min
MB Holding Register 33, Address: h32 = Bereich1 Max
MB Holding Register 34, Address: h33 = Range2 Min.
MB Holding Register 35, Address: h34 = Rereich2 Max.
MB Holding Register 36, Address: h35 = Range3 Min.
MB Holding Register 37, Address: h36 = Rereich3 Max.
Input Registers
MB Input Register 1, Address: i0 = Firmware
MB Input Register 2, Address: i1 = Product code 1
MB Input Register 3, Address: i2 = Parameterset ID (from FW 13)
MB Input Register 4-9, Address: i3 - i8 = Unique Device Signature 0 - 5
MB Input Register 10, Address: i9 = Parameterset Index (from FW 13)
MB Input Register 11, Address: i10 = Operation condition 1
MB Input Register 12, Address: i11 = Operation condition 2 (from FW 13)
MB Input Register 13, address: i12 = error status
MB Input Register 14, Address: i13 = Reserve
MB Input Register 15, Address: i14 = Speed
MB Input Register 21, Address: i20 = DC voltage
MB Input Register 22, Addresse: i21 = Line voltage
MB Input Register 23, Address: i22 = IGBT-temperature
MB Input Register 24, Addresse: i23 = inside temperature
MB Input Register 25, Address: i24 = MCU temperature
MB Input Register 26, Address: i25 = Motor temperature
MB Input Register 27, Address: i26 = E1 input
MB Input Register 28, Address: i27 = Modulation
MB Input Register 31, Address: i30 = Event
MB Input Register 32, Address: i31 = Event number
MB Input Register 34, Address: i33 = Motor input power
MB Input Register 50, Address: i49 = Inquiry PIN protect level
Operating Instructions AM-CAN-OPEN model series Enclosure
L-BAL-E199-GB 1846 Index 005 Part.-No. 00163405-GB
22/28