8 Enclosure
8.1 Technical data
Type
(Part-No.)
Rated current
Output
{1}
[A]
Rated current
(I fundamental
component @
50 Hz)
Input
{2}
[A]
Recommen-
ded motor
output
{3}
[kW]
Rated tempera-
ture
[°C]
max. line fuse
{4}
[A]
max. heat dis-
sipation
{2}
[W]
Weight
[kg]
FSDM5
(308340-UL)
5.0
4.7
(4.5)
2.2 55 10 80 3.42
FSDM7.5
(308341-UL)
7.5
6.3
(6.0)
3.0 50 10 120 3.47
FSDM8.5
(308342-UL)
8.5
7.3
(6.9)
4.0 40 10 140 3.47
FSDM12
(306622-UL)
12.0
11.0
(9.9)
5.5 55 16 175 6.1
FSDM17
(306623-UL)
17.0
15.3
(14.1)
7.5 50 20 260 6.1
FSDM25
(308309-UL)
25.0
22.8
(20.1)
11.0 55 35 430 18.6
FSDM32
(308310-UL)
32.0
28.3
(25.7)
15.0 50 35 560 19.6
FSDM39
(308311-UL)
39.0
34.1
(32.7)
18.5 40 50 730 22.6
FSDM46
(308312-UL)
46.0
37.5
(36.1)
22.0 40 50 900 22.7
1 Rated current output
current indication rating plate @ rated voltage, @ rated temperature @ rating switching frequency
(cos φ 0.8 at the output)
2 At rated voltage (cos φ 0.8 at the output), values for different specifications on request.
3 Example for power of a 4 pole motor. For the dimension of the frequency inverter size the rated current of the motor is
crucial!
4 Max. line fuse on site (line protection fuse) according to EN 60204-1 Classification VDE0113 Part 1 (see also Assembly
instructions / Electrical installation / Mains connection / Line protection fuse).
Line voltage* 3 ~ 208...480 V (-15 ... +10 %),
50/60 Hz
UL: 3 x 200...480 Vac, 50/60 Hz
Rated voltage 400 V
Maximal output voltage approx. 95 % from U
line
Maximal output frequency 50 Hz (1 - 120 Hz) **
Edgefrequency 50 Hz (1 - 120 Hz) **
U/f-characteristic curve linear (quadratic) **
Switching frequency 8 kHz (16 kHz permitted only after consultation with the manufacturer) **
Rating switching frequency 8 kHz
Rampup time 20 sec (1 - 250 sec) **
Rampdown time 20 sec (1 - 250 sec) **
Current limit 120 % (100 - 130 %) **
Power factor > 0.9
Input resistance for speed setting
signal
for input 0...10 V: R
i
> 100 kΩ
for input 0...20 mA: R
i
= 100 Ω
Voltage supply for external devices +24 V ± 20 %, I
max
70 mA
Power loss in standby operation approx. 3 W
Output 10 V I
max
10 mA (short-circuit-proof)
Operating Instructions PMIcontrol Basic-M – model series FSDM5...46 Enclosure
L-BAL-E300-GB 1905 Index 001 Part.-No.
39/48