EasyManua.ls Logo

Zline RG Series - FLAME ADJUSTMENT PROCEDURE; Step 9:

Zline RG Series
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Flame Adjustment Procedure
Step 9:
9a. Light one burner at a time and set it to the MINIMUM position (small flame).
9b. Remove the knob.
9c. The range is equipped with a safety valve. Using a small-size flathead
screwdriver, locate the choke screw (see diagram below) and turn to the right or left
until the burner flame is adjusted to desired minimum.
9d. Make sure that the flame does not go out when switching quickly from the
MAXIMUM to the MINIMUM position.
2.0 x 50 mm
2.0 x 50 mm
Flame Adjustment
The high flame setting cannot be adjusted to be lower. If the height is
too high, revisit the conversion set up. A step may have been missed.
Flame
Adjustment