8 In operation
When everything is installed and configured, the control-unit will operate the
gas cannon, according to your chosen settings. Each time power is set to the
control-unit, the first action will be starting a shots series. Wait with opening
the valve of the gas tank until you have finished configuration.
After opening the valve of the gas tank always push the red
button of the hose fracture protection valve, to make sure an
unobstructed gas flow is established.
On the circuit board of the control-unit you’ll find 2 LED’s. The led with the
character V beside it, will light during the time gas is injected into the cannon.
The led with the character B beside it, will light when the control-unit activates
the electronic ignition (this ignition will only be used on the Zon EL08).
Be careful, the explosion will follow in less then 2 seconds!!
Led V (open gas valve) Led B (ignition)
When the control-unit is powered on and the display is not lit, pushing the reset
button shortly will light the display and show the remaining time until the next
shots series. This time is descending and will be shown for 15 seconds.
During the time the display is lit, the control-unit will never operate the gas
cannon. Pay attention, if the display should turn to unlit at the moment a time
interval to the next series is passed, it will start operating the gas cannon im-
mediately.