Dazon bv
General
The conversion kit Zon 4MT08 creates the possibility to convert a fully mecha-
nical gas cannon into a semi-electronic gas cannon.
The electronic control-unit MT08 makes the propane gas cannon produce 1,
2, 3 or 4 shots series, with approximately 5 seconds between each shot.
The time-interval between consecutive series can be configured electronically
between 1 and 60 minutes. The equipment provides three different possibili-
ties to choose random intervals between shots series, in which case the control-
unit selects a different time-interval after each series.
The control-unit is equipped with a 24-hours clock. No less than 4 periods
can be configured, during which the control-unit will operate the propane gas
cannon.
Always wear ear-protection near cannons in operation!!
1 Contents of the conversion kit
1 MT08, electronic control-unit 1x
2 SBBV, hose fracture protection valve 1x
3 NH14, hose clamp 3x
4 User manual 1x
2 Aansluiten
1 Close the valve of the gas tank. Do not open this until you have
finished installation and configuration of the MT08!!
2 Disconnect the pressure regulator from the gas tank.
3 Disconnect the hose from the precise regulator.
4 Unscrew the precise regulator from the pressure regulator (unscrew is
clockwise).