Chapter 2 Technical Indexes
Confidential and Proprietary Information of ZTE CORPORATION 43
TABLE 22 RECEIVING INDEX OF ATM STM-1 MULTI-MODE OPTICAL
INTERFACE
Item
62.5/125 μmMMF
Unit
Wavelength (λ ?, range):
1,270 ~ 1,380 nm
Trise/Tfall (minimum, 10% ~ 90%)
0.6 ns
Trise/Tfall (maximum, 10% ~ 90%)
3.0 ns
Mean optical receiving power
(maximum)
-14 dBm
Receiving sensitivity -29 dBm
Protection Switching
Protection switching indexes contain:
Protection Mode
SDH Protection Switching
Protection Switching Criterion for Ethernet Services
ATM VP Protection Criterion and Index
Protection Mode
The system supports multiplex section protection (MSP), subnet
connection protection (SNCP), dual node interconnection (DNI)
protection, and L2 switching STP protection. MSP, SNCP, and
DNI protection comply with Recommendation G.841 and
Recommendation G.842.
SDH Protection Switching
MSP Criterion and Index
For the optical cable line system, the MSP criterion is as
follows: The protection time is less than 50 ms under one of
the circumstances below:
f Loss of signal (LOS)
f Loss Of Frame (LOF)
f Alarm Indication Signal (AIS)
f The bit error exceeding the threshold
f Signal deterioration
SNCP Switching Criterion and Index