ZXCLOUDR5300G3MaintenanceGuide
Table2-1AlarmLevels
LevelDescription
CriticalIndicatesthatthenormalserviceisaffectedseverelyandthatthealarmmustbe
clearedimmediately.
MajorIndicatesasymptomaffectingthenormalservice.Thisalarmmustbecleared
immediately.
MinorIndicatesthatafactornotaffectingthenormalservicesexistsinthesystem.
Correctiveactionsarerequiredtopreventworseproblems.
WarningIndicatesapotentialproblemoraproblemthatmayaffectthenormalservicesoon.
Adiagnosisisrequiredtopreventthealarmfrombecomingaworseproblemthat
affectsnormalserviceoperation.
Steps
1.OnthenavigationbarintheWebpageoftheBMC,selectAlarm>CurrentAlarm.
TheCurrentAlarmpageisdisplayed,seeFigure2-1.
Figure2-1CurrentAlarm
2.(Optional)UnderQueryFilter,selecttheltercriteria,andthenclickQuerytoquery
thecurrentalarmsmeetingthecriteria.
Ifnoltercriteriaareset,allcurrentalarmsaredisplayed.
3.(Optional)Selectoneormultiplecurrentalarms,andthenacknowledge,
unacknowledge,ordeletethem.
lAcknowledginganalarmconvertsthealarmfromtheUnacknowledgestatusto
theAcknowledgestatus.Itisrecommendedthatyouacknowledgeanalarm
beforeyouhandleit.
lIfyoucannotclearthealarm,youcanreturnthisalarmtotheunacknowledged
status.
–EndofSteps–
2-2
SJ-20150306151222-003|2015-03-20(R1.0)ZTEProprietaryandCondential