ZXMWNR8120A/8120DCongurationGuide
ParameterValueRangeDefault
Value
Description
NEHealthlNoAlarm
lMinor
Alarm
lMajor
Alarm
lCritical
Alarm
NoalarmDisplaysthecurrentdevicestatus.
Afterthistaskiscompleted,userscanlogintotheWebLMTthroughthe
RCMUC/RCMUD'sNMSinterface(theNMSinterfaceisOnandenabled).ThePC's
IPaddressandtheNE'sIPaddressmustbeconguredinthesamenetworksegment.
3.ClickApply.
–EndofSteps–
2.2ConguringtheNETime
Thisproceduredescribeshowtosetthesystemtimeandtimezone,whichprovidestime
referencesforfunctionssuchasfaultmanagementandperformancequery.Afterthetime
zoneischanged,thesystemtimeisupdatedautomatically.
Steps
ConguringtheNETimeZone
1.Intheleftpane,selectSetup>System>Time.Thesystemtimecongurationpage
isdisplayed,seeFigure2-2.
2-4
SJ-20150804150350-005|2015-10-23(R1.1)ZTEProprietaryandCondential