Chapter3DailyMaintenanceItems
Steps
1.Checkwhethertherearetheantistaticringhandlesinthecabinets.
2.Checkwhethertherearetheserialportcablesinthecabinets.
ReferenceStandards
Thereshouldbeoneserialportcableandoneantistaticringhandleatleastinacabinet.
Note:
TheserialportcableofZXR105900EandthoseofZTEswitchesandCiscoswitchesare
interchangeable.
3.4CheckingEquipmentBasicInformation
Purpose
Thistopicdescribeshowtocheckequipmentbasicinformation,andviewtheequipment
serviceloadsandtheoperationindicatorstolocatethehiddentroubles.
Steps
1.Checkthesoftwareversionandtheboardin-positionstatuses.
2.Checkalarminformation.
3.Checktheoperationallogs.
4.Checktheexceptionles.
ReferenceStandards
1.Runtheshowversioncommandtocheckthesoftwareversionandtheboardin-position
statuses.
Innormalsituations,thesoftwareversionandtheequipmentoperatingdurationare
thesameasthoserecordedbytheofcepersonnel.TheinstalledboardsareinOnline
status.
Iftheinformationisnotthesameorthereisanyexception,itisnecessarytondoutthe
causeimmediatelyandneedtroubleshootinginaccordancewiththerelatedguidance.
Forexample:
ZXR10#showversion
5950-56PM-HSoftware,5900Version:V3.00.10.B12,DEBUGSOFTWARE
Rosngplatformversion:V1.00.35(3.5.01).
Copyright(c)2010-2020byZTECorporation.
Compiled2014-6-16,17:38:55
3-3
SJ-20150114102049-013|2015-01-15(R1.0)ZTEProprietaryandCondential