ZXR105900ESeriesRoutineMaintenance
Systemimagefilesare:<ftp://168.0.0.178/HMPU.set>
Systemuptimeis0days,0hours,45minutes
[MP(M),shelf0,panel1]
cpu0
Mainprocessor:ARMMV78230Processor
BootromVersion:V1.21
Memory:2048Mbytes
SystemFlash:512Mbytes
Systembaud:9600baud
Systemnvram:8kbytes
CPUcardCPLD:N/A
CPLD1Version:V1.00
CPLD2Version:V1.00
BoardName:5950-56PM-H
BoardPCB:V1.00
2.Runtheshowloggingalarmcommandtocheckwhetherthereisanyalarminformation.
Innormalsituations,thereshouldbenoalarminformation.
Ifthereisanyalarminformation,itisnecessarytomakearecord.Foralarm
informationwhosealarmlevelislessthan5,itisnecessarytohandlethealarm
informationimmediately.
Forexample:
ZXR10#showloggingalarm
Analarm400304ID1level3occurredat00:03:3901-01-2010sentby56PM-112MP-0/1/0
%CHM%Powermalfunction!Shelfnum=0groupid=1powerid=1Powerisoffline
3.Runtheshowlogfilecommandtochecktheoperationallogs.
Innormalsituation,thereshouldbenoabnormaloperationallogs.Thenormal
operationallogsincludetheoperationtimes,useraccounts,loginIPandoperational
commands.
Forexample:
ZXR10#showlogfile
StartTime:00:46:3701-01-2010EndTime:00:46:4001-01-2010FlowID:43
VtyNo:con0UserName:UserLevel:15IP:HostName:56PM-112
Result:cease-dataCMDLevel:15CMDLine:shologfile
4.ChecktheExc_Omp.txt,Exc_pp.txtleinthe/ash/run_logdirectoryandtheles
intheEXCINFOfolder.
Innormalsituations,thereshouldbenonewgeneratedexceptioninformationrecord
les.
Ifthereisanynewexceptioninformationrecordlegeneratedafterthelastcheck,it
isnecessarytoanalyzethele.
Forexample:
ZXR10#cd/flash/run_log
3-4
SJ-20150114102049-013|2015-01-15(R1.0)ZTEProprietaryandCondential